Chapter 12: Trunk Configuration

Parameter

Description

 

 

 

 

Incoming Ring

Single—Default setting for North America

Type

Double—For countries using Ring-Ring-Silent type of ring

 

 

pattern

 

 

Centrex Flash

Specifies the Flash Duration time in milliseconds, with a range

Duration (ms)

from 50 ms to 1000 ms. This setting complements the Centrex

 

Flash Support option in the General tab for the trunk.

 

 

Detect Trunk

When selected, the analog trunk will check the loop current

Status By Loop

and if connected will change the state to “Idle.” If not selected,

Current

the trunk will check circuit DC voltage to determine the trunk

 

status. Do not change this setting without consulting with

 

AltiGen Technical Support.

 

 

Enable Caller ID

When selected, the system will wait for caller ID FSK signal

Receive

before answering the incoming call. In North America,

 

typically it takes two rings to receive the caller ID from the CO.

 

If your trunk does not have caller ID service, you can uncheck

 

this box to speed up the answering process.

 

 

Out of Service With

When checked, if the trunk is set to Out of Service, the system

Trunk Seizure

will busy out the trunk. The CO will treat this trunk as a busy

 

line and WILL NOT place a call to this trunk. (By default, this

 

option is unchecked.)

 

 

Call Setup

Select from:

 

Enable Dial Tone Detection (Outgoing)—When

 

enabled, the trunk channel must detect outgoing dial tone

 

prior to making the call.

 

Enable Answer Debounce (Incoming)—Enables a

 

timeout period of 2 seconds (for ignoring false CO

 

disconnect signal), after answering an incoming call.

 

 

Disconnect

Select from:

Supervision

Tone—busy tone (reorder tone, fast busy tone, error tone,

 

 

and so on) or dial tone (continuous tone, and so on). This

 

should be used in conjunction with drop in loop current. For

 

COs who cannot guarantee loop break, this may be the only

 

option.

 

Polarity Reversal—a reversed battery signal.

 

Loop Break Signal either 200 or 600. 600 ms is common

 

in North America.

 

 

Receive from CO

Slide setting adjusts the gain from the CO to the trunk from

(dB Gain)

0 dB to 7 dB for every Quantum Trunk channel.

 

The default setting is 0 dB, and it is highly recommended not

 

to change this setting.

 

Caution! Setting the volume too high will cause distortion in

 

voice quality and/or missed DTMF digits.

 

 

170AltiWare ACM 5.1 Administration Manual

Page 184
Image 184
AltiGen comm ACM 5.1 manual Receive from CO, DB Gain