AltiGen comm ACM 5.1 manual Parameter Description, Extension, Number Length, Default Password

Models: ACM 5.1

1 454
Download 454 pages 40.28 Kb
Page 69
Image 69

Chapter 4: System Configuration

To set the number plan, select System > System Configuration, then click the Number Plan tab.

Figure 2. System Configuration, Number Plan tab

Use the Number Plan tab to specify the following parameters:

Parameter

Description

 

 

 

 

Extension

The number of digits for your extension numbering system. Valid

Number Length

entries are from 3–6. For example, extension 2001 and 4020 are

 

4-digit extension numbers.

 

Note: Once the first extension is configured, the extension number

 

length cannot be changed without totally reconfiguring the

 

system or deleting all the extensions already configured.

 

Further, if a first digit dialed is assigned to extensions and

 

you have set up extensions beginning with that digit, you

 

cannot change the digit assignment without first deleting all

 

affected extensions. For example, if 7 is assigned to

 

Extension and you’re using extensions 7010, 7113, and so

 

on, you cannot reassign 7 to IP trunk access, without first

 

deleting all the 7nnn extensions.

 

 

Default Password

The default password for newly created extensions is randomly

 

generated by the system. (When the password is changed, it must

 

be four to eight digits in length.)

 

 

AltiWare ACM 5.1 Administration Manual 55

Page 69
Image 69