Chapter 11: Board Configuration

For information on configuring the T1/E1 trunk, see “Triton T1/E1 Trunk Properties” on page 157.

For information on configuring the Triton Analog Trunk, see “Triton Analog Trunk GS/ LS Properties” on page 160.

For information on configuring a Triton Analog Line, see “Triton Analog Station Line Properties” on page 200.

In the main Board Configuration dialog box for the MAX board (see Figure 20 on page 144) clicking the Board Configuration button opens the following dialog box.

Figure 21. MAX Board Configuration window

This dialog box displays the board serial number, top access card serial number, bottom access card serial number, DSP clock, board ID, physical ID, and logical ID. You can choose to configure the board as either T1 or Triton E1, then click OK. Additional steps are needed to further configure the CAS or PRI protocol in the Protocol Configuration window, shown in Figure 9 and Figure 10.

(For information on adding and removing mobile trunks, see “Mobile Extension Configuration” on page 239.)

Configuring the Virtual MobileExt Board

A simulated physical board—MobileExt board—is created if a Triton analog trunk or Triton T1/PRI trunk is configured as a MobileTrunk. T1, PRI and analog trunks can be shared for regular incoming and outgoing calls and mobile trunk connections.

Only one gateway can include a MobileExt board, even if the system consists of multiple gateways.

Configuring the virtual MobileExt board is discussed on page 240 in the chapter “Mobile Extension Configuration.”

AltiWare ACM 5.1 Administration Manual 145

Page 159
Image 159
AltiGen comm ACM 5.1 manual Configuring the Virtual MobileExt Board, MAX Board Configuration window