SDRAM Controller Operation

15.2.1 DRAM Controller Signals

Table 15-2describes the behavior of DRAM signals in synchronous mode.

 

 

 

 

 

 

 

 

Table 15-2. Synchronous DRAM Signal Connections

 

 

 

 

 

 

 

Signal

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

Synchronous row address strobe. Indicates a valid SDRAM row address is present and can be latched by the SDRAM.

 

SRAS

 

 

 

 

 

 

SRAS

should be connected to the corresponding SDRAM

SRAS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Synchronous column address strobe. Indicates a valid column address is present and can be latched by the SDRAM.

 

SCAS

 

 

 

 

 

 

 

SCAS

should be connected to the corresponding SDRAM

SCAS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DRAM read/write. Asserted for write operations and negated for read operations.

 

DRAMW

 

 

 

 

 

 

 

 

 

 

 

 

 

Row address strobe. Select each memory block of SDRAMs connected to the MCF5282. One

 

signal

 

SDRAM_CS[1:0]

 

SDRAM_CS

 

 

 

 

 

 

selects one SDRAM block and connects to the corresponding

CS

signals.

 

 

 

 

 

SCKE

 

Synchronous DRAM clock enable. Connected directly to the CKE (clock enable) signal of SDRAMs. Enables and

 

 

 

 

 

 

disables the clock internal to SDRAM. When CKE is low, memory can enter a power-down mode in which operations

 

 

 

 

 

 

are suspended or capable of entering self-refresh mode. SCKE functionality is controlled by DCR[COC]. For designs

 

 

 

 

 

 

using external multiplexing, setting COC allows SCKE to provide command-bit functionality.

 

 

 

 

BS[3:0]

Column address strobe. BS[3:0] function as byte enables to the SDRAMs. They connect to the BS signals (or mask

 

 

 

 

 

 

qualifiers) of the SDRAMs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15.2.2 Memory Map for SDRAMC Registers

The DRAM controller registers memory map is shown in Table 15-3.

Table 15-3. DRAM Controller Registers

IPSBAR

[31:24]

[23:16]

 

[15:8]

 

[7:0]

Offset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x040

DRAM control register (DCR) [p. 15-5]

 

 

 

 

 

 

 

 

 

0x044

 

 

 

 

 

 

 

0x048

 

DRAM address and control register 0 (DACR0) [p. 15-6]

 

 

 

 

 

0x04C

 

DRAM mask register block 0 (DMR0) [p. 15-8]

 

 

 

 

 

0x050

 

DRAM address and control register 1 (DACR1) [p. 15-6]

 

 

 

 

 

0x054

 

DRAM mask register block 1 (DMR1) [p. 15-8]

 

 

 

 

 

 

 

 

 

15-4

MCF5282 User’s Manual

MOTOROLA

Page 318
Image 318