Functional Description

1 TEST-LOGIC-RESET

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

0

RUN-TEST/IDLE

1

 

SELECT DR-SCAN

 

 

SELECT IR-SCAN

 

 

 

1

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

0

 

 

 

 

 

1

CAPTURE-DR

 

1

CAPTURE-IR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

0

 

 

 

 

 

 

SHIFT-DR

 

0

 

SHIFT-IR

 

0

 

 

 

 

1

 

 

 

1

 

 

 

 

 

 

EXIT1-DR

 

1

 

EXIT1-IR

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

0

 

 

 

 

 

 

PAUSE-DR

 

0

 

PAUSE-IR

 

0

 

 

 

 

1

 

 

 

1

 

 

 

 

 

0

EXIT2-DR

 

 

0

EXIT2-IR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

1

 

 

 

 

 

 

UPDATE-DR

 

 

UPDATE-IR

 

 

 

 

 

 

1

0

 

 

1

0

 

Figure 31-3. TAP Controller State Machine Flow

31.5.3 JTAG Instructions

Table 31-5describes public and private instructions.

 

 

 

Table 31-5. JTAG Instructions

 

 

 

 

 

 

 

 

 

Instruction

IR[3:0]

Instruction Summary

 

 

 

 

 

 

 

EXTEST

0000

Selects boundary scan register while applying fixed values to output pins and asserting

 

 

 

functional reset

 

 

 

 

 

 

 

 

 

IDCODE

0001

Selects IDCODE register for shift

 

 

 

 

 

 

 

SAMPLE/PRELOAD

0010

Selects boundary scan register for shifting, sampling, and preloading without

 

 

 

disturbing functional operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31-8

 

MCF5282 User’s Manual

MOTOROLA

Page 738
Image 738