Register Descriptions

 

Table 27-7. Queue 1 Operating Modes

 

 

MQ1[12:8]

Operating Mode

 

 

00000

Disabled mode, conversions do not occur

 

 

00001

Software-triggered single-scan mode (started with SSE1)

 

 

00010

External-trigger rising-edge single-scan mode

 

 

00011

External-trigger falling-edge single-scan mode

 

 

00100

Interval timer single-scan mode: time = QCLK period ⋅ 27

00101

Interval timer single-scan mode: time = QCLK period ⋅ 28

00110

Interval timer single-scan mode: time = QCLK period ⋅ 29

00111

Interval timer single-scan mode: time = QCLK period ⋅ 210

01000

Interval timer single-scan mode: time = QCLK period ⋅ 211

01001

Interval timer single-scan mode: time = QCLK period ⋅ 212

01010

Interval timer single-scan mode: time = QCLK period ⋅ 213

01011

Interval timer single-scan mode: time = QCLK period ⋅ 214

01100

Interval timer single-scan mode: time = QCLK period ⋅ 215

01101

Interval timer single-scan mode: time = QCLK period ⋅ 216

01110

Interval timer single-scan mode: time = QCLK period ⋅ 217

01111

Externally gated single-scan mode (started with SSE1)

 

 

10000

Reserved mode

 

 

10001

Software-triggered continuous-scan mode

 

 

10010

External-trigger rising-edge continuous-scan mode

 

 

10011

External-trigger falling-edge continuous-scan mode

 

 

10100

Periodic timer continuous-scan mode: time = QCLK period ⋅ 27

10101

Periodic timer continuous-scan mode: time = QCLK period ⋅ 28

10110

Periodic timer continuous-scan mode: time = QCLK period ⋅ 29

10111

Periodic timer continuous-scan mode: time = QCLK period ⋅ 210

11000

Periodic timer continuous-scan mode: time = QCLK period ⋅ 211

11001

Periodic timer continuous-scan mode: time = QCLK period ⋅ 212

11010

Periodic timer continuous-scan mode: time = QCLK period ⋅ 213

11011

Periodic timer continuous-scan mode: time = QCLK period ⋅ 214

11100

Periodic timer continuous-scan mode: time = QCLK period ⋅ 215

11101

Periodic timer continuous-scan mode: time = QCLK period ⋅ 216

11110

Periodic timer continuous-scan mode: time = QCLK period ⋅ 217

11111

Externally gated continuous-scan mode

 

 

MOTOROLA

Chapter 27. Queued Analog-to-Digital Converter (QADC)

27-15

Page 599
Image 599
Motorola MCF5281, MCF5282 user manual Queue 1 Operating Modes