SDRAM Controller Operation

 

 

 

Table 15-5. DACRn Field Descriptions (continued)

 

 

 

 

 

 

 

 

 

Bit

Name

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

10–8

CBM

Command and bank MUX [2:0]. Because different SDRAM configurations cause the command and bank select

 

 

lines to correspond to different addresses, these resources are programmable. CBM determines the addresses onto

 

 

which these functions are multiplexed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CBM

 

Command Bit

Bank Select Bits

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000

 

17

18 and up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

001

 

18

19 and up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

010

 

19

20 and up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

011

 

20

21 and up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

21

22 and up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

101

 

22

23 and up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110

 

23

24 and up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

111

 

24

25 and up

 

 

 

 

 

 

 

 

 

 

This encoding and the address multiplexing scheme handle common SDRAM organizations. Bank select bits

 

 

include a base bit and all address bits above for SDRAMs with multiple bank select bits.

 

 

 

 

 

 

 

 

7

Reserved, should be cleared.

 

 

 

 

 

 

 

 

 

 

6

IMRS

Initiate mode register set (MRS) command. Setting IMRS generates a MRS command to the associated SDRAMs.

 

 

In initialization, IMRS should be set only after all DRAM controller registers are initialized and PALL and

 

 

REFRESH commands have been issued. After IMRS is set, the next access to an SDRAM block programs the

 

 

SDRAM’s mode register. Thus, the address of the access should be programmed to place the correct mode

 

 

information on the SDRAM address pins. Because the SDRAM does not register this information, it doesn’t

 

 

matter if the IMRS access is a read or a write or what, if any, data is put onto the data bus. The DRAM controller

 

 

clears IMRS after the MRS command finishes.

 

 

 

 

 

0

Take no action

 

 

 

 

 

1

Initiate MRS command

 

 

 

 

 

 

 

 

 

 

5–4

PS

Port size. Indicates the port size of the associated block of SDRAM, which allows for dynamic sizing of

 

 

associated SDRAM accesses. PS functions the same in asynchronous operation.

 

 

00

32-bit port

 

 

 

 

 

01

8-bit port

 

 

 

 

 

1x

16-bit port

 

 

 

 

 

 

 

 

 

 

3

IP

Initiate precharge all (PALL) command. The DRAM controller clears IP after the PALL command is finished.

 

 

Accesses via IP should be no wider than the port size programmed in PS.

 

 

0

Take no action.

 

 

 

 

 

1 A PALL command is sent to the associated SDRAM block. During initialization, this command is executed

 

 

 

after all DRAM controller registers are programmed. After IP is set, the next write to an appropriate SDRAM

 

 

 

address generates the PALL command to the SDRAM block.

 

 

 

 

 

 

 

 

 

 

2–0

Reserved, should be cleared.

 

 

 

 

 

 

 

 

 

 

 

 