Image 557

 

 

 

Programmer’s Model

 

 

 

Table 25-18. IMASK Field Descriptions

 

 

 

 

Bits

Name

 

Description

 

 

 

15–0

BUFnM

IMASK contains one interrupt mask bit per buffer. It allows the CPU to designate which buffers will

 

 

generate interrupts after successful transmission/reception.

 

 

0

The interrupt for the corresponding buffer is disabled.

 

 

1

The interrupt for the corresponding buffer is enabled.

 

 

 

 

25.5.10 Interrupt Flag Register (IFLAG)

IFLAG contains one interrupt flag bit per buffer. Each successful transmission/reception sets the corresponding IFLAG bit and, if the corresponding IMASK bit is set, will generate an interrupt.

This register contains two 8-bit fields: bits 15-8 (IFLAG_H) and bits 7-0 (IFLAG_L). The register can be accessed by the master as a 16-bit register, or each byte can be accessed individually using an 8-bit (byte) access cycle.

 

15

14

13

12

11

10

9

8

Field

BUF15I

BUF14I

BUF13I

BUF1I

 

BUF11I

BUF10I

BUF9I

BUF8I

 

 

 

 

 

 

 

 

 

Reset

 

 

 

0000_0000

 

 

 

 

 

 

 

 

 

 

 

 

 

R/W

 

 

 

 

R/w

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

6

5

4

3

 

 

0

Field

BUF7I

BUF6I

BUF5I

BUF4I

 

BUF3I

BUF2I

BUF1I

BUF0I

 

 

 

 

 

 

 

 

 

Reset

 

 

 

0000_0000

 

 

 

 

 

 

 

 

 

 

 

 

R/W

 

 

 

 

R/W

 

 

 

 

 

 

 

 

 

 

 

Address

 

 

 

IPSBAR + 0x1C_0024

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 25-15. Interrupt Flag Register (IFLAG)

Table 25-19describes the IFLAG fields.

 

 

Table 25-19. IFLAG Field Descriptions

 

 

 

Bits

Name

Description

 

 

 

15–0

BUFnI

IFLAG contains one interrupt flag bit per buffer. Each successful transmission/reception sets the

 

 

corresponding IFLAG bit and, if the corresponding IMASK bit is set, an interrupt request will be

 

 

generated.

 

 

To clear an interrupt flag, first read the flag as a one, and then write it as a zero. Should a new flag

 

 

setting event occur between the time that the CPU reads the flag as a one and writes the flag as a

 

 

zero, the flag is not cleared. This register can be written to zeros only.

 

 

0 The interrupt for the corresponding buffer is disabled.

 

 

1 The interrupt for the corresponding buffer is enabled.

 

 

 

MOTOROLA

Chapter 25. FlexCAN

25-31

Page 557