Functional Overview

If the RXCTR increases to a value greater than 127, it is no longer incremented, even if more errors are detected while being a receiver. At the next successful message reception, the counter is set to a value between 119 and 127, in order to return to Error Active state.

25.4.10 FlexCAN Initialization Sequence

Initialization of the FlexCAN includes the initial configuration of the message buffers and configuration of the CAN communication parameters following a reset, as well as any reconfiguration which may be required during operation. The following is a generic initialization sequence for the FlexCAN:

1.Initialize all operation modes

a)Initialize the transmit and receive pin modes in control register 0 (CANCTRL0).

b)Initialize the bit timing parameters PROPSEG, PSEGS1, PSEG2, and RJW in control registers 1 and 2 (CANCTRL[1:2]).

c)Select the S-clock rate by programming the PRESDIV register.

d)Select the internal arbitration mode (LBUF bit in CANCTRL1).

2.Initialize message buffers

a)The control/status word of all message buffers must be written either as an active or inactive message buffer.

b)All other entries in each message buffer should be initialized as required.

3.Initialize mask registers for acceptance mask as needed

4.Initialize FlexCAN interrupt handler

a)Initialize the interrupt configuration register (CANICR) with a specific request level and vector base address.

b)Set the required mask bits in the IMASK register (for all message buffer interrupts), in CANCTRL0 (for bus off and error interrupts), and in CANMCR for the WAKE interrupt.

5.Negate the HALT bit in the module configuration register

a)At this point, the FlexCAN will attempt to synchronize with the CAN bus.

NOTE

In both the transmit and receive processes, the first action in preparing a message buffer should be to deactivate the buffer by setting its code field to the proper value. This requirement is mandatory to assure data coherency.

25-16

MCF5282 User’s Manual

MOTOROLA