QADC Electrical Characteristics

Table 33-6. QADC Electrical Specifications (Operating) 1 (Continued)

(VDDH and VDDA = 5.0 Vdc ± 0.5V, VDD = 2.7-3.6V, VSS and VSSA = 0 Vdc, FQCLK = 2.0 MHz, TA within operating temperature range)

Parameter

Symbol

Min

Max

Unit

 

 

 

 

 

Input Voltage

VINDC

VSSA–0.3

VDDA + 0.3

V

Input High Voltage, PQA and PQB

VIH

0.7 (VDDA)

VDDA + 0.3

V

Input Low Voltage, PQA and PQB

VIL

VSSA – 0.3

0.4(VDDA)

V

Input Hysteresis, PQA, PQB 3

VHYS

0.5

V

Output High Voltage, PQA/PQB 3

VOH

 

 

V

IOH = TBD

 

VDDH-0.8

 

 

 

 

 

 

 

 

 

 

Analog Supply Current

IDDA

 

 

 

Normal Operation 4

 

5.0

mA

Low-Power Stop

 

10.0

A

 

 

 

 

 

Reference Supply Current, DC

IREF

250

µA

Reference Supply Current, Transient

IREF

2.0

mA

Load Capacitance, PQA/PQB

CL

50

pF

Input Current, Channel Off 5

IOFF

-200

200

nA

Total Input Capacitance 6

C

 

 

pF

PQA Not Sampling

IN

15

 

 

 

PQB Not Sampling

 

10

 

Incremental Capacitance added during sampling

 

5

 

 

 

 

1QADC converter specifications are only guaranteed for VDDH and VDDA = 5.0V +/- 0.5V. VDDH and VDDA may be powered down to 2.7V with only GPIO functions supported.

2To obtain full-scale, full-range results, VSSA VRL VINDC VRH VDDA

3Parameter applies to the following pins:

Port A: PQA[4:3]/AN[56:55]/ETRIG[2:1], PQA[1:0]/AN[53:52]/MA[1:0]

Port B: PQB[3:0]/AN[3:0]/AN[Z:W]

4Current measured at maximum system clock frequency with QADC active.

5Maximum leakage occurs at maximum operating temperature. Current decreases by approximately one-half for each 8 to 12° C, in the ambient temperature range of 50 to 125 °C.

6This parameter is characterized before qualification rather than 100% tested.

33-8

MCF5282 User’s Manual

MOTOROLA

Page 758
Image 758