232CHAPTER 25: MIRRORING CONFIGURATION GUIDE
Network Diagram Figure 69 Network diagram for remote port mirroring
Switch A | Switch B | Switch C |
Reflector |
|
| |||
port | Eth1/0/3 | Eth1/0/1 | |||
Eth1/0/4 |
|
|
| Eth1/0/1 | Eth1/0/2 |
|
| ||||
|
|
|
| ||
Eth1/0/1 |
|
|
| Eth1/0/2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Eth1/0/2
Networking and
Configuration
Requirements
Dept. 1 Dept. 2 | Data monitoring device |
The departments of a company connect to each other through Switch 5500s:
■Switch A, Switch B, and Switch C are Switch 5500s.
■Department 1 is connected to Ethernet 1/0/1 of Switch A.
■Department 2 is connected to Ethernet 1/0/2 of Switch A.
■Ethernet 1/0/3 of Switch A connects to Ethernet 1/0/1 of Switch B.
■Ethernet 1/0/2 of Switch B connects to Ethernet 1/0/1 of Switch C.
■Data monitoring device is connected to Ethernet 1/0/2 of Switch C.
The administrator wants to monitor the packets sent from Department 1 and 2 through the data monitoring device.
Use the remote port mirroring function to meet the requirement. Perform the following configurations:
■Use Switch A as the source switch, Switch B as the intermediate switch, and Switch C as the destination switch.
■On Switch A, create a remote source mirroring group, configure VLAN 10 as the
■On Switch B, configure VLAN 10 as the
■Configure Ethernet 1/0/3 of Switch A, Ethernet 1/0/1 and Ethernet 1/0/2 of Switch B, and Ethernet 1/0/1 of Switch C as Trunk ports, allowing packets of VLAN 10 to pass.
■On Switch C, create a remote destination mirroring group, configure VLAN 10 as the
Applicable Products
Product series | Software version | Hardware version |
|
|
|
Switch 5500 | Release V03.02.04 | All versions |
Switch 5500G | Release V03.02.04 | All versions |
Switch 4210 |