32. Electrical Characteristics
Rev.1.00 Jan. 10, 2008 Page 1567 of 1658
REJ09B0261-0100
32.3 AC Characteristics
In principle, this LSI's input should be synchronous. Unless specified otherwise, ensure that the
setup time and hold times for each input signal are observed.
Table 32.5 Clock Timing
Item Symbol Min. Typ. Max. Unit
CPU, FPU, cache, TLB f 1 603 MHz
DDR2-SDRAM bus 200 302
External bus 1 101
Operating
frequency
PCI bus DC 67
Peripheral modules 1 51