19. Display Unit (DU)
Rev.1.00 Jan. 10, 2008 Page 865 of 1658
REJ09B0261-0100
19.3.10 Horizontal Display End Register (HDER) The horizontal display end register (HDER) sets the horizontal display end position. The value is retained during power-on reset and manual reset.
R/W:
Internal update:
R/W:
Internal update:
161718192021222324252627282931 30Bit:
Initial value:
RRRRRRRRRRRRRRRR
0000000000000000
R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WRRRRR
OOOOOOOOOOO
00000
HDE
— —
01234567891011121315 14Bit:
Initial value:
Bit Bit Name
Initial
Value R/W
Internal
Update Description
31 to 11 All 0 R Reserved
These bits are always read as 0. The write value
should always be 0.
10 to 0 HDE Undefined R/W Yes Horizontal Display End
The horizontal display end position should be
set in dot clock units.