Siemens 440 manual Setpoint source, P10003 Selection of frequency setpoint

Models: 440

1 328
Download 328 pages 28.01 Kb
Page 110
Image 110

Parameter Description

Issue 01/06

3.16Setpoint source

P1000[3]

Selection of frequency setpoint

 

Min:

0

 

CStat:

CT

Datatype: U16

Unit: -

Def:

2

 

P-Group:

SETPOINT

Active: first confirm

QuickComm.: Yes

Max:

77

Level

1

Selects frequency setpoint source. In the table of possible settings below, the main setpoint is selected from the least significant digit (i.e., 0 to 7) and any additional setpoint from the most significant digit (i.e., x0 through to x7).

Possible Settings:

0No main setpoint

1MOP setpoint

2Analog setpoint

3Fixed frequency

4USS on BOP link

5USS on COM link

6CB on COM link

7Analog setpoint 2

10

No main setpoint

+ MOP setpoint

11

MOP setpoint

+ MOP setpoint

12

Analog setpoint

+

MOP setpoint

13

Fixed frequency

+ MOP setpoint

14

USS on BOP link

+ MOP setpoint

15

USS on COM link

+ MOP setpoint

16

CB on COM link

+ MOP setpoint

17

Analog setpoint 2

+

MOP setpoint

20

No main setpoint

+

Analog setpoint

21

MOP setpoint

+

Analog setpoint

22

Analog setpoint

+

Analog setpoint

23

Fixed frequency

+

Analog setpoint

24

USS on BOP link

+ Analog setpoint

25

USS on COM link

+ Analog setpoint

26

CB on COM link

+ Analog setpoint

27

Analog setpoint 2

+

Analog setpoint

30

No main setpoint

+

Fixed frequency

31

MOP setpoint

+ Fixed frequency

32

Analog setpoint

+

Fixed frequency

33

Fixed frequency

+

Fixed frequency

34

USS on BOP link

+ Fixed frequency

35

USS on COM link

+ Fixed frequency

36

CB on COM link

+ Fixed frequency

37

Analog setpoint 2

+

Fixed frequency

40

No main setpoint

+ USS on BOP link

41

MOP setpoint

+ USS on BOP link

42

Analog setpoint

+ USS on BOP link

43

Fixed frequency

+ USS on BOP link

44

USS on BOP link

+ USS on BOP link

45

USS on COM link

+ USS on BOP link

46

CB on COM link

+ USS on BOP link

47

Analog setpoint 2

+ USS on BOP link

50

No main setpoint

+ USS on COM link

51

MOP setpoint

+ USS on COM link

52

Analog setpoint

+ USS on COM link

53

Fixed frequency

+ USS on COM link

54

USS on BOP link

+ USS on COM link

55

USS on COM link

+ USS on COM link

57

Analog setpoint 2

+ USS on COM link

60

No main setpoint

+ CB on COM link

61

MOP setpoint

+ CB on COM link

62

Analog setpoint

+ CB on COM link

63

Fixed frequency

+ CB on COM link

64

USS on BOP link

+ CB on COM link

66

CB on COM link

+ CB on COM link

67

Analog setpoint 2

+ CB on COM link

70

No main setpoint

+

Analog setpoint 2

71

MOP setpoint

+

Analog setpoint 2

72

Analog setpoint

+

Analog setpoint 2

73

Fixed frequency

+

Analog setpoint 2

74

USS on BOP link

+ Analog setpoint 2

75

USS on COM link

+ Analog setpoint 2

76

CB on COM link

+ Analog setpoint 2

77

Analog setpoint 2

+

Analog setpoint 2

110

MICROMASTER 440 Parameter List

6SE6400-5BB00-0BP0

Page 110
Image 110
Siemens 440 manual Setpoint source, P10003 Selection of frequency setpoint