MICROMASTER 440 Parameter List 6SE6400-5BB00-0BP0

Parameter Description

Issue 01/06

r1204

Status word: Flying start V/f

 

Min:

-

 

Datatype: U16

Unit: -

Def:

-

 

P-Group: FUNC

 

Max:

-

Level

4

Bit parameter for checking and monitoring states during search, if V/f control mode is selected (see P1300).

 

Bitfields:

 

 

 

 

 

 

 

 

 

Bit00

Current applied

 

0

NO

1

YES

 

 

Bit01

Current could not be applied

 

0

NO

1

YES

 

 

Bit02

Voltage reduced

 

0

NO

1

YES

 

 

Bit03

Slope-filter started

 

0

NO

1

YES

 

 

Bit04

Current less threshold

 

0

NO

1

YES

 

 

Bit05

Current-minimum

 

0

NO

1

YES

 

 

Bit07

Speed could not be found

 

0

NO

1

YES

r1205

 

Status word: Flying start SLVC

 

 

Min:

-

 

Level

 

 

 

Datatype: U16

Unit: -

 

Def:

-

 

3

 

 

P-Group:

FUNC

 

 

Max:

-

 

 

 

 

Bit parameter for checking status of flying start performed with n-adaption of observer. Parameter is only

 

 

valid, if sensorless vector control (SLVC) is selected (see P1300).

 

 

 

 

 

 

Bitfields:

 

 

 

 

 

 

 

 

 

Bit00

Transformation active

 

0

NO

1

YES

 

 

Bit01

Initialize n-adaption

 

0

NO

1

YES

 

 

Bit02

Current applying

 

0

NO

1

YES

 

 

Bit03

N-controller closed

 

0

NO

1

YES

 

 

Bit04

Isd-controller open

 

0

NO

1

YES

 

 

Bit05

RFG hold

 

0

NO

1

YES

 

 

Bit06

N-adaption set to zero

 

0

NO

1

YES

 

 

Bit07

Reserved

 

0

NO

1

YES

 

 

Bit08

Reserved

 

0

NO

1

YES

 

 

Bit09

Reserved

 

0

NO

1

YES

 

 

Bit10

Direction Positive

 

0

NO

1

YES

 

 

Bit11

Search is started

 

0

NO

1

YES

 

 

Bit12

Current is applied

 

0

NO

1

YES

 

 

Bit13

Search is aborted

 

0

NO

1

YES

 

 

Bit14

Deviation is zero

 

0

NO

1

YES

 

 

Bit15

N-controller is active

 

0

NO

1

YES