Siemens 440 manual R1725 CO Integral limit of Isd ctrl, R1728 CO Decoupling voltage

Models: 440

1 328
Download 328 pages 28.01 Kb
Page 183
Image 183

Issue 01/06

Parameter Description

r1725

CO: Integral limit of Isd ctrl.

 

Min:

-

 

Datatype: Float

Unit: V

Def:

-

 

P-Group: CONTROL

 

Max:

-

Level

4

Displays limit of integral output voltage setpoint of Isd current controller.

r1728

CO: Decoupling voltage

 

Min:

-

 

Datatype: Float

Unit: V

Def:

-

 

P-Group: CONTROL

 

Max:

-

Displays actual output voltage setpoint of cross channel decoupling.

Level

4

P1740

Gain for oscillation damping

 

Min:

0.000

 

CStat:

CUT

Datatype: Float

Unit: -

Def:

0.000

 

P-Group:

CONTROL

Active: Immediately

QuickComm.: No

Max:

10.000

Level

3

Sets the controller gain to dampen oscillations in the sensorless vector control (SLVC) at low frequencies (open-loop).

isq

-

Dependency:

Siehe P1750, P1755, P1756

P1740

P1740

T

f res damping

P1745[3] Variance flux error

 

 

Min:

0.0

CStat:

CUT

Datatype: Float

Unit: %

Def:

5.0

P-Group:

CONTROL

Active: Immediately

QuickComm.: No

Max:

1000.0

Level

3

Allowed variance error between flux setpoint and measured flux.

Index:

P1745[0] : 1st. Drive data set (DDS)

P1745[1] : 2nd. Drive data set (DDS)

P1745[2] : 3rd. Drive data set (DDS)

r1746

CO: Variance flux error

 

Min:

-

Level

 

Datatype: Float

Unit: %

Def:

-

3

 

 

 

P-Group: CONTROL

 

Max:

-

 

Variance error between flux setpoint and measured flux.

3.29.2.9Motor model

P1750[3] Control word of motor model

 

Min:

0

CStat:

CUT

Datatype: U16

Unit: -

Def:

0

P-Group:

CONTROL

Active: first confirm

QuickComm.: No

Max:

3

Level

3

Control word of motor model. This parameter controls the operation of the sensorless vector control (SLVC) at very low frequencies. This therefore includes the following conditions:

-Operation directly after an ON command

-zero crossing.

f

Start

f

Zero crossing

 

Closed loop

 

Closed loop

P1755

 

P1755

 

 

Open loop

 

Open loop

 

t

 

t

 

 

 

P1755

MICROMASTER 440

Parameter List

6SE6400-5BB00-0BP0

183

Page 183
Image 183
Siemens 440 manual R1725 CO Integral limit of Isd ctrl, R1728 CO Decoupling voltage, P1740 Gain for oscillation damping