Siemens 440 manual P13213 Programmable V/f volt. coord, P13223 Programmable V/f freq. coord

Models: 440

1 328
Download 328 pages 28.01 Kb
Page 160
Image 160

Parameter Description

 

 

 

 

Issue 01/06

 

 

 

 

 

 

P1321[3] Programmable V/f volt. coord. 1

 

Min:

0.0

 

Level

 

CStat:

CUT

Datatype: Float

Unit: V

Def:

0.0

 

3

 

 

 

 

P-Group:

CONTROL

Active: Immediately

QuickComm.: No

Max:

3000.0

 

 

 

See P1320 (programmable V/f freq. coord. 1).

 

 

 

 

 

Index:

 

 

 

 

 

 

 

 

P1321[0]

: 1st. Drive data set (DDS)

 

 

 

 

 

 

P1321[1]

: 2nd. Drive data set (DDS)

 

 

 

 

 

 

P1321[2]

: 3rd. Drive data set (DDS)

 

 

 

 

 

P1322[3] Programmable V/f freq. coord. 2

 

Min:

0.00

 

Level

 

CStat:

CT

Datatype: Float

Unit: Hz

Def:

0.00

 

3

 

 

 

 

P-Group:

CONTROL

Active: Immediately

QuickComm.: No

Max:

650.00

 

 

 

See P1320 (programmable V/f freq. coord. 1).

 

 

 

 

 

Index:

 

 

 

 

 

 

 

 

P1322[0]

: 1st. Drive data set (DDS)

 

 

 

 

 

 

P1322[1]

: 2nd. Drive data set (DDS)

 

 

 

 

 

 

P1322[2]

: 3rd. Drive data set (DDS)

 

 

 

 

 

P1323[3] Programmable V/f volt. coord. 2

 

Min:

0.0

 

Level

 

CStat:

CUT

Datatype: Float

Unit: V

Def:

0.0

 

3

 

P-Group:

CONTROL

Active: Immediately

QuickComm.: No

Max:

3000.0

 

 

 

See P1320 (programmable V/f freq. coord. 1).

 

 

 

 

 

Index:

 

 

 

 

 

 

 

 

P1323[0]

: 1st. Drive data set (DDS)

 

 

 

 

 

 

P1323[1]

: 2nd. Drive data set (DDS)

 

 

 

 

 

 

P1323[2]

: 3rd. Drive data set (DDS)

 

 

 

 

 

P1324[3] Programmable V/f freq. coord. 3

 

Min:

0.00

 

Level

 

CStat:

CT

Datatype: Float

Unit: Hz

Def:

0.00

 

3

 

 

 

 

P-Group:

CONTROL

Active: Immediately

QuickComm.: No

Max:

650.00

 

 

 

See P1320 (programmable V/f freq. coord. 1).

 

 

 

 

 

Index:

 

 

 

 

 

 

 

 

P1324[0]

: 1st. Drive data set (DDS)

 

 

 

 

 

 

P1324[1]

: 2nd. Drive data set (DDS)

 

 

 

 

 

 

P1324[2]

: 3rd. Drive data set (DDS)

 

 

 

 

 

P1325[3] Programmable V/f volt. coord. 3

 

Min:

0.0

 

Level

 

CStat:

CUT

Datatype: Float

Unit: V

Def:

0.0

 

3

 

P-Group:

CONTROL

Active: Immediately

QuickComm.: No

Max:

3000.0

 

 

See P1320 (programmable V/f freq. coord. 1).

Index:

P1325[0] : 1st. Drive data set (DDS)

P1325[1] : 2nd. Drive data set (DDS)

P1325[2] : 3rd. Drive data set (DDS)

P1330[3]

CI: Voltage setpoint

 

 

Min:

0:0

 

CStat:

T

Datatype: U32

Unit: -

Def:

0:0

 

P-Group:

CONTROL

Active: first confirm

QuickComm.: No

Max:

4000:0

Level

3

BICO parameter for selecting source of voltage setpoint for independent V/f control.

Index:

P1330[0] : 1st. Command data set (CDS)

P1330[1] : 2nd. Command data set (CDS)

P1330[2] : 3rd. Command data set (CDS)

160

MICROMASTER 440 Parameter List

6SE6400-5BB00-0BP0

Page 160
Image 160
Siemens 440 P13213 Programmable V/f volt. coord, P13223 Programmable V/f freq. coord, P13233 Programmable V/f volt. coord