Siemens 440 manual P15003 Selection of torque setpoint, 173, Example P1500 =

Models: 440

1 328
Download 328 pages 28.01 Kb
Page 173
Image 173

Issue 01/06

Parameter Description

3.29.2.4Torque control

P1500[3] Selection of torque setpoint

 

Min:

0

CStat:

CT

Datatype: U16

Unit: -

Def:

0

P-Group:

CONTROL

Active: first confirm

QuickComm.: Yes

Max:

77

Level

2

Selects torque setpoint source. In the table of possible settings below, the main setpoint is selected from the least significant digit (i.e., 0 to 7) and any additional setpoint from the most significant digit (i.e., x0 through to x7).

Possible Settings:

0No main setpoint

2Analog setpoint

4USS on BOP link

5USS on COM link

6CB on COM link

7Analog setpoint 2

20

No main setpoint

+

Analog setpoint

22

Analog setpoint

+

Analog setpoint

24

USS on BOP link

+ Analog setpoint

25

USS on COM link

+ Analog setpoint

26

CB on COM link

+ Analog setpoint

27

Analog setpoint 2

+

Analog setpoint

40

No main setpoint

+ USS on BOP link

42

Analog setpoint

+ USS on BOP link

44

USS on BOP link

+ USS on BOP link

45

USS on COM link

+ USS on BOP link

46

CB on COM link

+ USS on BOP link

47

Analog setpoint 2

+ USS on BOP link

50

No main setpoint

+ USS on COM link

52

Analog setpoint

+ USS on COM link

54

USS on BOP link

+ USS on COM link

55

USS on COM link

+ USS on COM link

57

Analog setpoint 2

+ USS on COM link

60

No main setpoint

+ CB on COM link

62

Analog setpoint

+ CB on COM link

64

USS on BOP link

+ CB on COM link

66

CB on COM link

+ CB on COM link

67

Analog setpoint 2

+ CB on COM link

70

No main setpoint

+

Analog setpoint 2

72

Analog setpoint

+

Analog setpoint 2

74

USS on BOP link

+ Analog setpoint 2

75

USS on COM link

+ Analog setpoint 2

76

CB on COM link

+ Analog setpoint 2

77

Analog setpoint 2

+

Analog setpoint 2

Index:

P1500[0] : 1st. Command data set (CDS)

P1500[1] : 2nd. Command data set (CDS)

P1500[2] : 3rd. Command data set (CDS)

Example:

Setting 24 selects the main setpoint (4) derived from the USS on BOP link with the additional setpoint (2) derived from the analog input. Single digits are main setpoints only with no additional setpoint.

Example P1500 = 24 :

P1500 = 24

P1503

= 755.0

P1503 CI: Torque setpoint

r0755

CO: Act. ADC after scal. [4000h]

 

 

 

 

 

 

 

P1500 = 24

P1511

= r2015.1

P1511 CI: Additional torque setpoint

 

 

r2015

CO: PZD from BOP link (USS)

 

 

 

 

 

 

 

 

ADC

 

USS

 

BOP link

 

USS

P1000 = 24

COM link

 

CB

 

COM link

P1000 = 24

ADC2

 

MICROMASTER 440 Parameter List

 

6SE6400-5BB00-0BP0

 

Additonal torque setpoint

Torque setpoint

Sequence control

Torque control

173

Page 173
Image 173
Siemens 440 manual P15003 Selection of torque setpoint, 173, Example P1500 =