Issue 01/06

 

 

 

Parameter Description

 

 

 

 

 

P0627[3] Overtemperature stator winding

 

Min:

20.0

Level

 

CStat:

CUT

Datatype: Float

Unit: °C

Def:

80.0

4

 

 

 

P-Group:

MOTOR

Active: Immediately

QuickComm.: No

Max:

200.0

 

Overtemperature of the stator winding.

Index:

P0627[0] : 1st. Drive data set (DDS)

P0627[1] : 2nd. Drive data set (DDS)

P0627[2] : 3rd. Drive data set (DDS)

Note:

Temperature rise:

The losses occurring in the motor are converted into heat (thermal energy). This is the reason that permissible limit temperature rises are defined for windings and other mechanical parts and components of the motors. The temperature rise of the motor is defined as the difference between the temperature of a motor component (e.g. rotor winding) and the temperature of the cooling medium (e.g. ambient air temperature) (EN 60034-1). The temperature rise determined by the motor manufacturer by making the appropriate measurements is the difference between the temperature of the winding at the end of the measurement and the temperature of the cooling medium.

ϑ ü = ϑ 2 ϑ K

ϑ ü :

Temperature rise

 

ϑ 2 :

Temperature at the end of the measurement

 

ϑ K :

Cooling-medium temperature

The permissible temperature rises of the windings is classified in insulating classes. The insulating class valid for the particular motor is specified on the motor rating plate.

The following points should be carefully observed:

-The temperature rises of the stator/rotor winding are only applicable for sinusoidal operation (basic fundamental).

-The temperature of stator/rotor winding rises when the motor is fed with a sinusoidal voltage as well as also losses (modulation losses, losses due to harmonics) caused as a result of drive converter operation.

-The value may only be modified if the motor is in the cold condition (ambient temperature). The motor identification run should be carried-out after the value has been changed.

P0628[3]

Overtemperature rotor winding

 

Min:

20.0

Level

 

 

CStat:

CUT

Datatype: Float

Unit: °C

Def:

100.0

4

 

 

P-Group:

MOTOR

Active: Immediately

QuickComm.: No

Max:

200.0

 

 

Index:

Overtemperature of the rotor winding.

 

 

 

 

 

P0628[0]

: 1st. Drive data set (DDS)

 

 

 

 

 

 

 

 

 

 

 

 

P0628[1]

: 2nd. Drive data set (DDS)

 

 

 

 

 

 

P0628[2]

: 3rd. Drive data set (DDS)

 

 

 

 

 

Note:

See parameter P0627

 

 

 

 

 

 

 

 

 

 

 

 

r0630[3]

CO: Ambient temperature

 

Min:

-

Level

 

 

 

 

Datatype: Float

Unit: °C

Def:

-

4

 

 

P-Group:

MOTOR

 

 

Max:

-

 

Displays ambient temperature of motor mass model.

Index:

r0630[0] : 1st. Drive data set (DDS)

r0630[1] : 2nd. Drive data set (DDS)

r0630[2] : 3rd. Drive data set (DDS)

r0631[3]

CO: Stator iron temperature

 

Min:

-

Level

 

Datatype: Float

Unit: °C

Def:

-

4

 

 

 

P-Group: MOTOR

 

Max:

-

 

Displays iron temperature of motor mass model.

Index:

r0631[0] : 1st. Drive data set (DDS)

r0631[1] : 2nd. Drive data set (DDS)

r0631[2] : 3rd. Drive data set (DDS)

r0632[3]

CO: Stator winding temperature

 

Min:

-

Level

 

Datatype: Float

Unit: °C

Def:

-

4

 

P-Group: MOTOR

 

Max:

-

 

Displays stator winding temperature of motor mass model.

Index:

r0632[0] : 1st. Drive data set (DDS)

r0632[1] : 2nd. Drive data set (DDS)

r0632[2] : 3rd. Drive data set (DDS)

MICROMASTER 440

Parameter List

6SE6400-5BB00-0BP0

73

Page 73
Image 73
Siemens 440 P06273 Overtemperature stator winding, P06283 Overtemperature rotor winding, R06303 CO Ambient temperature