P1021[3] BI: Fixed freq. selection Bit 1

 

Min:

0:0

CStat:

CT

Datatype: U32

Unit: -

Def:

0:0

P-Group:

COMMANDS

Active: first confirm

QuickComm.: No

Max:

4000:0

Defines origin of fixed frequency selection.

Index:

P1021[0] : 1st. Command data set (CDS)

P1021[1] : 2nd. Command data set (CDS)

P1021[2] : 3rd. Command data set (CDS)

Dependency:

Accessible only if P0701 - P0706 = 99 (function of digital inputs = BICO)

Details:

See P1020 (fixed frequency selection Bit 0) for most common settings

Level

3

P1022[3] BI: Fixed freq. selection Bit 2

 

Min:

0:0

CStat:

CT

Datatype: U32

Unit: -

Def:

0:0

P-Group:

COMMANDS

Active: first confirm

QuickComm.: No

Max:

4000:0

Defines origin of fixed frequency selection.

Index:

P1022[0] : 1st. Command data set (CDS)

P1022[1] : 2nd. Command data set (CDS)

P1022[2] : 3rd. Command data set (CDS)

Dependency:

Accessible only if P0701 - P0706 = 99 (function of digital inputs = BICO)

Details:

See P1020 (fixed frequency selection Bit 0) for most common settings

Level

3

P1023[3] BI: Fixed freq. selection Bit 3

 

Min:

0:0

CStat:

CT

Datatype: U32

Unit: -

Def:

722:3

P-Group:

COMMANDS

Active: first confirm

QuickComm.: No

Max:

4000:0

Defines origin of fixed frequency selection.

Index:

P1023[0] : 1st. Command data set (CDS)

P1023[1] : 2nd. Command data set (CDS)

P1023[2] : 3rd. Command data set (CDS)

Dependency:

Accessible only if P0701 - P0706 = 99 (function of digital inputs = BICO)

Details:

See P1020 (fixed frequency selection Bit 0) for most common settings

Level

3

r1024

CO: Act. fixed frequency

 

Min:

-

 

Datatype: Float

Unit: Hz

Def:

-

 

P-Group: SETPOINT

 

Max:

-

Displays sum total of selected fixed frequencies.

Level

3

P1025[3] Fixed frequency mode - Bit 4

 

Min:

1

CStat:

CT

Datatype: U16

Unit: -

Def:

1

P-Group:

SETPOINT

Active: first confirm

QuickComm.: No

Max:

2

Direct selection or direct selection + ON for bit 4

Possible Settings:

1Direct selection

2Direct selection + ON command

Index:

P1025[0] : 1st. Command data set (CDS)

P1025[1] : 2nd. Command data set (CDS)

P1025[2] : 3rd. Command data set (CDS)

Details:

See parameter P1001 for description of how to use fixed frequencies.

Level

3

P1026[3] BI: Fixed freq. selection Bit 4

 

Min:

0:0

CStat:

CT

Datatype: U32

Unit: -

Def:

722:4

P-Group:

COMMANDS

Active: first confirm

QuickComm.: No

Max:

4000:0

Defines origin of fixed frequency selection.

Index:

P1026[0] : 1st. Command data set (CDS)

P1026[1] : 2nd. Command data set (CDS)

P1026[2] : 3rd. Command data set (CDS)

Dependency:

Accessible only if P0701 - P0706 = 99 (function of digital inputs = BICO).

Details:

See P1020 (fixed frequency selection Bit 0) for most common settings.

Level

3

118

MICROMASTER 440 Parameter List

6SE6400-5BB00-0BP0

Page 118
Image 118
Siemens 440 P10213 BI Fixed freq. selection Bit, P10223 BI Fixed freq. selection Bit, P10233 BI Fixed freq. selection Bit