Issue 01/06 | Parameter Description |
P0347[3] Demagnetization time |
|
| Min: | 0.000 | |
CStat: | CUT | Datatype: Float | Unit: s | Def: | 1.000 |
MOTOR | Active: Immediately | QuickComm.: No | Max: | 20.000 |
Defines the
Level
3
The
ON |
|
OFF1 | t |
OFF2 |
|
inactive |
|
active | t |
f | OFF2 |
| Motor coasts down |
| t |
| P0347 |
Index:
P0347[0] : 1st. Drive data set (DDS)
P0347[1] : 2nd. Drive data set (DDS)
P0347[2] : 3rd. Drive data set (DDS)
Note:
-The
-The
-It is not active after a normal
-If this time is excessively shortened, then the drive inverter will be tripped (shut down) due to an overcurrent condition.
-If a synchronous motor is connected, the
P0350[3] | Stator resistance |
| Min: | 0.00001 | ||
| CStat: | CUT | Datatype: Float | Unit: Ohm | Def: | 4.00000 |
|
| MOTOR | Active: Immediately | QuickComm.: No | Max: | 2000.00000 |
Level
2
Stator resistance value in [Ohms] for connected motor (from
P0350 = 2 ⋅ (RCable + RS )
There are three ways to determine the value for this parameter:
1.Calculate using
-P0340 = 1 (data entered from rating plate) or
-P0010 = 1, P3900 = 1,2 or 3 (end of quick commissioning).
2.Measure using P1910 = 1 (motor data identification - value for stator resistance is overwritten).
3.Measure manually using an Ohmmeter.
Index:
P0350[0] : 1st. Drive data set (DDS)
P0350[1] : 2nd. Drive data set (DDS)
P0350[2] : 3rd. Drive data set (DDS)
Note:
-Since measured
-The value entered in P0350 (stator resistance) is the one obtained by the method last used.
-Default value is depending on inverter type and its rating data.