Issue 01/06

Parameter Description

3.9Digital inputs

P0701[3] Function of digital input 1

 

Min:

0

CStat:

CT

Datatype: U16

Unit: -

Def:

1

P-Group:

COMMANDS

Active: first confirm

QuickComm.: No

Max:

99

Selects function of digital input 1.

DIN channel(e.g. DIN1 - PNP (P0725 = 1))

Level

2

Kl.9

PNP/NPN DIN

P24 (PNP)

0 ... 1

Kl.28

P0725 (1)

0 V (NPN)

 

Debounce time: DIN

P0701

24

V

0

0

24 V

1

1

 

0 ...

3

 

 

P0724 (3)

 

 

 

 

 

 

T

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

&

Function

r0722 Pxxxx BI : ...

r0722 .0 CO/BO: Bin.inp.val

0 V

Possible Settings:

0Digital input disabled

1ON/OFF1

2ON reverse /OFF1

3

OFF2 - coast to standstill

4OFF3 - quick ramp-down

9Fault acknowledge

10JOG right

11JOG left

12Reverse

13MOP up (increase frequency)

14MOP down (decrease frequency)

15Fixed setpoint (Direct selection)

16Fixed setpoint (Direct selection + ON)

17Fixed setpoint (Binary coded selection + ON)

25DC brake enable

29External trip

33Disable additional freq setpoint

99Enable BICO parameterization

Index:

P0701[0] : 1st. Command data set (CDS)

P0701[1] : 2nd. Command data set (CDS)

P0701[2] : 3rd. Command data set (CDS)

Dependency:

Setting 99 (enable BICO parameterization) requires

-P0700 command source or

-P0010 = 1, P3900 = 1, 2 or 3 quick commissioning or

-P0010 = 30, P0970 = 1 factory reset in order to reset.

Notice:

Setting 99 (BICO) for expert use only.

MICROMASTER 440

Parameter List

6SE6400-5BB00-0BP0

77

Page 77
Image 77
Siemens 440 manual Digital inputs, P07013 Function of digital input, DIN channele.g. DIN1 PNP P0725 =