Issue 01/06

Parameter Description

P2201[3] Fixed PID setpoint 1

 

 

Min:

-200.00

CStat:

CUT

Datatype: Float

Unit: %

Def:

0.00

P-Group:

TECH

Active: Immediately

QuickComm.: No

Max:

200.00

Defines Fixed PID Setpoint 1

Level

2

There are three options available for selection of the PID fixed setpoints:

1.Direct selection

2.Direct selection + ON command

3.Binary coded selection + ON command

1.Direct selection (P0701 - P0706 = 15):

-In this mode of operation, 1 digital input selects one PID fixed setpoint.

-If several inputs are active together, the selected setpoints are summed.

-E.g.: PID-FF1 + PID-FF2 + PID-FF3 + PID-FF4 + PID-FF5 + PID-FF6.

2.Direct selection + ON command (P0701 - P0706 = 16):

-In this mode of operation the PID fixed setpoints are combined with an ON command.

-Description as for 1), except that this type of selection issues an ON command concurrent with any setpoint selection.

-If several inputs are active together, the selected setpoints are summed.

-E.g.: PID-FF1 + PID-FF2 + PID-FF3 + PID-FF4 + PID-FF5 + PID-FF6.

3.Binary coded selection + ON command (P0701 - P0706 = 17):

-Using this method to select the fixed PID setpoint (FF-PID) allows you to choose up to 16 different PID setpoints.

-The setpoints are selected according to the following table:

Index:

P2201[0] : 1st. Drive data set (DDS)

P2201[1] : 2nd. Drive data set (DDS)

P2201[2] : 3rd. Drive data set (DDS)

Example:

Binary coded selection :

 

 

DIN4

DIN3

DIN2

DIN1

0 %

PID - FF0

0

0

0

0

P1001

PID - FF1

0

0

0

1

P1002

PID - FF2

0

0

1

0

P1003

PID - FF3

0

0

1

1

P1004

PID - FF4

0

1

0

0

P1005

PID - FF5

0

1

0

1

P1006

PID - FF6

0

1

1

0

P1007

PID - FF7

0

1

1

1

P1008

PID - FF8

1

0

0

0

P1009

PID - FF9

1

0

0

1

P1010

PID - FF10

1

0

1

0

P1011

PID - FF11

1

0

1

1

P1012

PID - FF12

1

1

0

0

P1013

PID - FF13

1

1

0

1

P1014

PID - FF14

1

1

1

0

P1015

PID - FF15

1

1

1

1