P2159[3] Threshold frequency f_3

 

Min:

0.00

CStat:

CUT

Datatype: Float

Unit: Hz

Def:

30.00

P-Group:

ALARMS

Active: Immediately

QuickComm.: No

Max:

650.00

Threshold_3 for comparing frequency to thresholds.

Level

2

f_act <= f_3 f_act > f_3

f_act

Tconst. speed filt

0 ... 1000 [ms] P2153.D (5)

 

Threshold freq f_3

 

0.00 ... 650.00 [Hz]

r2169

P2159.D (30.00)

 

 

 

1

 

Threshold freq f_3

{

0

 

 

 

 

0.00 ... 650.00 [Hz]

 

 

 

P2159.D (30.00)

Hyst . freq. f_hys

 

 

 

 

0.00 ... 10.00

[Hz]

 

1

P2150.D (3.00)

 

 

 

 

{

0

 

 

 

Hyst. freq. f_hys

0.00... 10.00 [Hz] P2150.D (3.00)

Delay time of f _3 0 ... 10000 [ms] P2160.D (10)

T 0

T 0

Delay time of f _3 0 ... 10000 [ms] P2160.D (10)

f_act <= f_3 r2198 Bit02

f_act > f_3 r2198 Bit03

Index:

 

P2159[0]

: 1st. Drive data set (DDS)

P2159[1]

: 2nd. Drive data set (DDS)

P2159[2]

: 3rd. Drive data set (DDS)

P2160[3] Delay time of threshold freq f_3

 

Min:

0

Level

 

CStat:

CUT

Datatype: U16

Unit: ms

Def:

10

2

 

 

 

P-Group:

ALARMS

Active: Immediately

QuickComm.: No

Max:

10000

 

Delay time for comparing frequency to threshold f_3 (P2159).

Index:

P2160[0] : 1st. Drive data set (DDS)

P2160[1] : 2nd. Drive data set (DDS)

P2160[2] : 3rd. Drive data set (DDS)

Details:

See diagram in P2159 (threshold frequency f_3)

P2161[3]

Min. threshold for freq. setp.

 

Min:

0.00

Level

 

CStat:

CUT

Datatype: Float

Unit: Hz

Def:

3.00

2

 

 

 

P-Group:

ALARMS

Active: Immediately

QuickComm.: No

Max:

10.00

 

Minimum threshold value for comparing frequency setpoint.

f_set <= P2161

Setp.min.threshold

0.00... 10.00 [Hz] P2161.D (3.00)

f_set

 

1

f_set <= P2161

{

0

r2198 Bit04

f_set > 0

Index:

0

 

1

0

{

Hyst . freq. f_hys

0.00... 10.00 [Hz] P2150.D (3.00)

Hyst . freq. f_hys

 

0.00 ... 10.00 [Hz]

f_set > 0

P2150.D (3.00)

 

r2198 Bit05

P2161[0] : 1st. Drive data set (DDS)

P2161[1] : 2nd. Drive data set (DDS)

P2161[2] : 3rd. Drive data set (DDS)

212

MICROMASTER 440 Parameter List

6SE6400-5BB00-0BP0

Page 212
Image 212
Siemens 440 P21593 Threshold frequency f3, P21603 Delay time of threshold freq f3, P21613 Min. threshold for freq. setp