Parameter Description

Issue 01/06

Conversion: T-equivalent curcuit -->

Invers - Γ - equivalent circuit

kσ R =

1+ Lσ R

 

 

Lm

 

LmΓ =

Lm

 

 

kσ R

 

 

 

RRΓ = RR k2σ R

Lσ = Lσ S + Lσ R kσ R

Conversion:

Invers - Γ -

equivalent circuit -->

T-equivalent curcuit

kσ Γ =

1+ (1kσ )

Lσ

= 1+ 0.5

Lσ

 

 

 

LmΓ

 

 

 

LmΓ

 

RR =

Rk2σΓ

 

 

 

 

 

Lσ S =

kσ Lσ = 0.5 Lσ

 

 

 

Lσ R = (1kσ ) Lσ kσ Γ = 0.5 Lσ kσ Γ

Rated motor impedance:

ZN =

V ph

=

VN

=

P0304

<=>100%

I ph

3

I

3 P0305

 

 

 

 

 

 

 

N

 

 

 

P0362[3] Magnetizing curve flux 1

 

Min:

0.0

CStat:

CUT

Datatype: Float

Unit: %

Def:

60.0

P-Group:

MOTOR

Active: Immediately

QuickComm.: No

Max:

300.0

Level

4

Specifies first flux value of saturation characteristic in [%] relative to rated motor voltage (P0304).

The parameter settings for the values of P0362 to P0365 respectively P0366 to P0369 are illustrated in the diagram below.

Φ [%]

 

 

 

 

 

P0365

 

 

 

 

 

P0364

 

 

 

 

 

100 %

 

 

 

 

 

P0363

 

 

 

 

 

P0362

 

 

 

 

 

0

 

 

 

iµ [%] =

iµ [A]

P0366 P0367 100 % P0368

P0369

iµ [%]

r0331

 

 

Index:

P0362[0] : 1st. Drive data set (DDS)

P0362[1] : 2nd. Drive data set (DDS)

P0362[2] : 3rd. Drive data set (DDS)

Note:

-P0362 = 100 % corresponds to rated motor flux

-Rated flux = rated EMF

-The value belongs to the first magnetizing current value and must be smaller than or equal to magnetizing curve flux 2 (P0363).

-If the magnetization values entered in P0362 to P0365 respectively P0366 to P0369 do not match the conditions (see below), a linear characteristic is applied internally.

P0365 P0364 P0363 P0362

P0369 P0368 P0367 P0366

P0363[3] Magnetizing curve flux 2

 

Min:

0.0

Level

 

CStat:

CUT

Datatype: Float

Unit: %

Def:

85.0

4

 

 

 

P-Group:

MOTOR

Active: Immediately

QuickComm.: No

Max:

300.0

 

Specifies second flux value of saturation characteristic in [%] relative to rated motor voltage (P0304).

Index:

P0363[0] : 1st. Drive data set (DDS)

P0363[1] : 2nd. Drive data set (DDS)

P0363[2] : 3rd. Drive data set (DDS)

Details:

See P0362 (magnetizing curve flux 1).

62

MICROMASTER 440 Parameter List

6SE6400-5BB00-0BP0

Page 62
Image 62