Issue 01/06

Parameter Description

P2174[3] Torque threshold M_thresh

 

Min:

0.00

CStat:

CUT

Datatype: Float

Unit: Nm

Def:

5.13

P-Group:

ALARMS

Active: Immediately

QuickComm.: No

Max:

99999.00

Defines torque threshold for comparing actual torque.

Level

2

M_act > M_thresh

M_actNoAcc > M_thresh

M_act

1

 

 

0

 

Delay time torque

 

 

M_act > M_thresh

 

0 ... 10000 [ms]

 

 

 

 

P2176.D (10)

 

 

r2198 Bit10

 

 

 

 

 

 

 

 

 

 

M_actNoAcc

 

 

 

 

T 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

&

> M_thresh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

r2198 Bit09

 

 

 

 

 

 

 

 

 

 

 

 

Delay_T rampUpCmpl

 

 

 

 

 

 

f_act

+

f_set

Torque threshold

0.00... 99999.00 [Nm] P2174.D (5.13)

Entry freq . deviat

0.00... 20.00 [Hz] P2163.D (3.00)

1

0

{

0 ... 10000 [ms] P2166.D (10)

Ramp-up completed

 

T 0

 

 

(active -high)

SET

 

 

 

 

 

 

 

 

 

 

 

(Q=1)

Q

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RFG active

 

RESET

 

 

 

 

 

 

 

 

 

 

 

 

 

(Q=0)

Q

Priority

1 RESET

2 SET

 

 

 

Hyster freq deviat

 

 

 

 

 

 

 

0.00 ... 10.00 [Hz]

 

 

 

 

 

 

 

P2164.D (3.00)

 

 

 

 

Index:

P2174[0]

: 1st. Drive data set (DDS)

 

 

 

 

 

 

 

 

 

 

P2174[1]

: 2nd. Drive data set (DDS)

 

 

 

 

 

P2174[2]

: 3rd. Drive data set (DDS)

 

 

 

 

P2176[3]

Delay time for torque threshold

 

Min:

0

Level

 

CStat:

CUT

Datatype: U16

Unit: ms

Def:

10

2

 

P-Group:

ALARMS

Active: Immediately

QuickComm.: No

Max:

10000

 

 

Index:

Delay time for comparing actual torque to threshold.

 

 

 

 

P2176[0]

: 1st. Drive data set (DDS)

 

 

 

 

 

 

 

 

 

 

P2176[1]

: 2nd. Drive data set (DDS)

 

 

 

 

 

P2176[2]

: 3rd. Drive data set (DDS)

 

 

 

 

P2177[3]

Delay time for motor is blocked

 

Min:

0

Level

 

CStat:

CUT

Datatype: U16

Unit: ms

Def:

10

2

 

P-Group:

ALARMS

Active: Immediately

QuickComm.: No

Max:

10000

 

 

Index:

Delay time for identification that motor is blocked.

 

 

 

 

P2177[0]

: 1st. Drive data set (DDS)

 

 

 

 

 

 

 

 

 

 

P2177[1]

: 2nd. Drive data set (DDS)

 

 

 

 

 

P2177[2]

: 3rd. Drive data set (DDS)

 

 

 

 

P2178[3]

Delay time for motor pulled out

 

Min:

0

Level

 

CStat:

CUT

Datatype: U16

Unit: ms

Def:

10

2

 

 

 

P-Group:

ALARMS

Active: Immediately

QuickComm.: No

Max:

10000

 

Delay time for identification that motor is pulled out.

Index:

P2178[0] : 1st. Drive data set (DDS)

P2178[1] : 2nd. Drive data set (DDS)

P2178[2] : 3rd. Drive data set (DDS)

MICROMASTER 440

Parameter List

6SE6400-5BB00-0BP0

217

Page 217
Image 217
Siemens 440 manual P21743 Torque threshold Mthresh, P21763 Delay time for torque threshold