Issue 01/06

Parameter Description

P1058[3] JOG frequency right

 

 

Min:

0.00

CStat:

CUT

Datatype: Float

Unit: Hz

Def:

5.00

P-Group:

SETPOINT

Active: Immediately

QuickComm.: No

Max:

650.00

Level

2

Jogging increases the motor frequency by small amounts. The JOG buttons uses a non-latching switch on one of the digital inputs to control the motor frequency.

If JOG clockwise (jogging clockwise) or JOG counter-clockwise is selected, the speed is increased until the value, set in P1058 is reached.

 

 

 

 

 

 

A0923

A0923

 

 

"1"

 

 

 

 

 

DIN

JOG right

 

 

 

 

t

 

P1055

"0"

 

 

 

 

 

BOP

 

(0)

 

 

 

 

 

 

 

 

 

 

 

 

USS

 

"1"

 

 

 

 

 

JOG left

 

 

 

 

t

BOP link

 

 

 

 

P1056

"0"

 

 

 

 

USS

 

 

 

 

 

 

(0)

f

 

 

 

 

COM link

 

P1082

 

 

 

 

CB

 

 

 

 

 

 

 

P1058

 

 

 

 

 

COM link

 

 

 

 

 

 

 

 

 

 

 

 

 

t

 

 

P1059

P1060

P1061

P1060

P1061

 

 

 

-P1082

 

 

 

 

 

 

 

 

Index:

P1058[0] : 1st. Drive data set (DDS)

P1058[1] : 2nd. Drive data set (DDS)

P1058[2] : 3rd. Drive data set (DDS)

Dependency:

P1060 and P1061 set up and down ramp times respectively for jogging.

P1059[3] JOG frequency left

 

 

Min:

0.00

CStat:

CUT

Datatype: Float

Unit: Hz

Def:

5.00

P-Group:

SETPOINT

Active: Immediately

QuickComm.: No

Max:

650.00

Level

2

While JOG left is selected, this parameter determines the frequency at which the inverter will run.

Index:

P1059[0] : 1st. Drive data set (DDS)

P1059[1] : 2nd. Drive data set (DDS)

P1059[2] : 3rd. Drive data set (DDS)

Dependency:

P1060 and P1061 set up and down ramp times respectively for jogging.

MICROMASTER 440

Parameter List

6SE6400-5BB00-0BP0

123

Page 123
Image 123
Siemens 440 manual P10583 JOG frequency right, P10593 JOG frequency left, 123