Issue 01/06

Parameter Description

r0948[12] CO: Fault time

 

Min:

-

 

Datatype: U16

Unit: -

Def:

-

 

P-Group: ALARMS

 

Max:

-

 

Time stamp to indicate when the fault has occurred.

 

 

 

Index:

 

 

 

Level

3

r0948[0]

:

Recent fault trip --, time stamp

r0948[1]

:

Recent fault trip --, time stamp

r0948[2]

:

Recent fault trip --, time stamp

r0948[3]

:

Recent fault trip -1, time stamp

r0948[4]

:

Recent fault trip -1, time stamp

r0948[5]

:

Recent fault trip -1, time stamp

r0948[6]

:

Recent fault trip -2, time stamp

r0948[7]

:

Recent fault trip -2, time stamp

r0948[8]

:

Recent fault trip -2, time stamp

r0948[9]

:

Recent fault trip -3, time stamp

r0948[10] : Recent fault trip -3, time stamp

r0948[11] : Recent fault trip -3, time stamp

Details:

Parameter r2114 (runtime counter) is a possible source of the time stamp. When using the runtime counter, the time is entered into the first two indices of the fault trip (shutdown) essentially the same as for r2114.

Time stamp when using r2114 (Refer to parameter r2114):

r0948[0]

: Last fault trip --, system time, seconds, upper word

r0948[1]

: Last fault trip --, system time, seconds, lower word

r0948[2]

: 0

r0948[3]

: Last fault trip --, system time, seconds, upper word

r0948[4]

: Last fault trip --, system time, seconds, lower word

r0948[5]

: 0

r0948[6]

: Last fault trip --, system time, seconds, upper word

r0948[7]

: Last fault trip --, system time, seconds, lower word

r0948[8]

: 0

r0948[9]

: Last fault trip --, system time, seconds, upper word

r0948[10]

: Last fault trip --, system time, seconds, lower word

r0948[11]

: 0

Parameter P2115 (AOP real-time clock) is an additional possible source of the time stamp. When using the real-time counter, instead of the system runtime r2114[0] and r2114[1], the value of the real-time clock P2115[0] to P2115[2] is read-in.

If the contents of parameter P2115 = 0, then the system assumes that there was no synchronization with the real time. In this case, if there is a fault, values are transferred from parameter r2114 into parameter P0948. If the contents of parameter P2115 are not equal to zero, then a synchronization with real time has taken place. In this case, if there is a fault, the values from parameter P2115 are transferred into parameter P0948.

Time stamp when using P2115 (Refer to parameter P2115 (AOP real-time clock)):

r0948[0]

: Last fault trip --, fault time, seconds + minutes

r0948[1]

: Last fault trip --, fault time, hours + days

r0948[2]

: Last fault trip --, fault time, month + year

r0948[3]

: Last fault trip -1, fault time, seconds + minutes

r0948[4]

: Last fault trip -1, fault time, hours + days

r0948[5]

: Last fault trip -1, fault time, month + year

r0948[6]

: Last fault trip -2, fault time, seconds + minutes

r0948[7]

: Last fault trip -2, fault time, hours + days

r0948[8]

: Last fault trip -2, fault time, month + year

r0948[9]

: Last fault trip -3, fault time, seconds + minutes

r0948[10]

: Last fault trip -3, fault time, hours + days

r0948[11]

: Last fault trip -3, fault time, month + year

r0949[8]

CO: Fault value

 

Min:

-

 

Datatype: U16

Unit: -

Def:

-

 

P-Group: ALARMS

 

Max:

-

Level

3

Displays drive fault values. It is for service purposes and indicate the type of fault reported. The values are listed in the code where faults are reported.

Index:

 

r0949[0]

: Recent fault trip --, fault value 1

r0949[1]

: Recent fault trip --, fault value 2

r0949[2]

: Recent fault trip -1, fault value 3

r0949[3]

: Recent fault trip -1, fault value 4

r0949[4]

: Recent fault trip -2, fault value 5

r0949[5]

: Recent fault trip -2, fault value 6

r0949[6]

: Recent fault trip -3, fault value 7

r0949[7]

: Recent fault trip -3, fault value 8

MICROMASTER 440 Parameter List

6SE6400-5BB00-0BP0

107

Page 107
Image 107
Siemens 440 manual R094812 CO Fault time, R09498 CO Fault value, 107