Example:

P2115[0] = 13625

P2115[1] = 2579

P2115[2] = 516

The conversion into binary quantities (U16) results in the following bit pattern:

Seconds + minutes:

-High byte (MSB) = 00110101 corresponding to the number 53, i.e. seconds 53

-Low byte (LSB) = 00111001 corresponding to the number 57, i.e. minutes 57

Hours + days:

-High byte (MSB) = 00001010 corresponding to the number 10, i.e. hours 10

-Low byte (LSB) = 00010011 corresponding to the number 19, i.e. days 19

Months + year:

-High byte (MSB) = 00000010 corresponding to the number 2, i.e. months 2

-Low byte (LSB) = 00000100 corresponding to the number 4, i.e. years 4

This means that the real time displayed in P2115 is 19.02.2004, 10:57:53.

P2120

Indication counter

 

 

Min:

0

 

CStat:

CUT

Datatype: U16

Unit: -

Def:

0

 

P-Group:

ALARMS

Active: Immediately

QuickComm.: No

Max:

65535

Level

4

Indicates total number of alarm events. This parameter is incremented whenever an alarm event occurs. It also gets incremented when a warning is cleared or faults are cleared.

This parameter is used by the PC tools.

P2150[3] Hysteresis frequency f_hys

 

Min:

0.00

Level

 

CStat:

CUT

Datatype: Float

Unit: Hz

Def:

3.00

3

 

P-Group:

ALARMS

Active: Immediately

QuickComm.: No

Max:

10.00

 

Defines hysteresis level applied for comparing frequency and speed to threshold as illustrated in the diagram below.

f_act > 0

f_act

0

 

1

0

{

f_act > 0

r2197 Bit03

r0052 Bit14

Hyst. freq. f_hys

0.00 ... 10.00 [Hz] P2150.D (3.00)

f_set

-

 

0

 

 

1

f_act >= f_set

0

{

r2197 Bit04

 

 

r0053 Bit06

f_act >= f_set

1

-1

Hyst . freq. f_hys

0.00... 10.00 [Hz] P2150.D (3.00)

Index:

 

P2150[0]

: 1st. Drive data set (DDS)

P2150[1]

: 2nd. Drive data set (DDS)

P2150[2]

: 3rd. Drive data set (DDS)

P2153[3] Time-constant frequency filter

 

Min:

0

Level

 

CStat:

CUT

Datatype: U16

Unit: ms

Def:

5

2

 

P-Group:

ALARMS

Active: Immediately

QuickComm.: No

Max:

1000

 

Specifies time constant of first-order frequency filter. The filtered frequency is then compared to the thresholds.

Index:

P2153[0] : 1st. Drive data set (DDS)

P2153[1] : 2nd. Drive data set (DDS)

P2153[2] : 3rd. Drive data set (DDS)

Details:

See diagram in P2155, P2157 and P2159

210

MICROMASTER 440 Parameter List

6SE6400-5BB00-0BP0

Page 210
Image 210
Siemens 440 manual P2120 Indication counter, P21503 Hysteresis frequency fhys, P21533 Time-constant frequency filter, 210