Issue 01/06

 

 

 

Parameter Description

 

 

 

 

 

 

P0095[10] CI: Display PZD signals

 

 

Min:

0:0

Level

 

CStat:

CT

Datatype: U32

Unit: -

Def:

0:0

3

 

 

 

P-Group:

CONTROL

Active: first confirm

QuickComm.: No

Max:

4000:0

 

Selects source of display for PZD signals.

Index:

 

 

P0095[0]

:

1st PZD signal

P0095[1]

:

2nd PZD signal

P0095[2]

:

3rd PZD signal

P0095[3]

:

4th PZD signal

P0095[4]

:

5th PZD signal

P0095[5]

:

6th PZD signal

P0095[6]

:

7th PZD signal

P0095[7]

:

8th PZD signal

P0095[8]

:

9th PZD signal

P0095[9]

:

10th PZD signal

r0096[10] PZD signals

 

Min:

-

Level

 

 

 

Datatype: Float

Unit: %

Def:

-

3

 

P-Group:

CONTROL

 

Max:

-

 

 

Displays PZD signals in [%].

 

 

 

 

Index:

 

 

 

 

 

 

 

r0096[0]

:

1st PZD signal

 

 

 

 

 

r0096[1]

:

2nd PZD signal

 

 

 

 

 

r0096[2]

:

3rd PZD signal

 

 

 

 

 

r0096[3]

:

4th PZD signal

 

 

 

 

 

r0096[4]

:

5th PZD signal

 

 

 

 

 

r0096[5]

:

6th PZD signal

 

 

 

 

 

r0096[6]

:

7th PZD signal

 

 

 

 

 

r0096[7]

:

8th PZD signal

 

 

 

 

 

r0096[8]

:

9th PZD signal

 

 

 

 

 

r0096[9]

:

10th PZD signal

 

 

 

 

Note:

r0096 = 100 % corresponds to 4000 hex.

MICROMASTER 440

Parameter List

6SE6400-5BB00-0BP0

41

Page 41
Image 41
Siemens 440 manual P009510 CI Display PZD signals, R009610 PZD signals, CStat Datatype U32 Unit Def Group