Parameter Description

Issue 01/06

Caution:

Be aware, by changing of parameter P1500 all BICO parameters (see table below) are modified.

Note:

Changing this parameter sets (to default) all settings on item selected (see table).

 

 

 

 

 

 

P1500 = xy

 

 

 

 

 

 

y = 0

y = 2

 

y = 4

y = 5

y = 6

y = 7

 

 

x = 0

 

0.0

755.0

 

2015.1

2018.1

2050.1

755.1

P1503

 

 

0.0

0.0

 

0.0

0.0

0.0

0.0

P1511

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x = 2

 

0.0

755.0

 

2015.1

2018.1

2050.1

755.1

P1503

 

 

755.0

755.0

 

755.0

755.0

755.0

755.0

P1511

 

 

 

 

xy

x = 4

 

0.0

755.0

 

2015.1

2018.1

2050.1

755.1

P1503

 

2015.1

2015.1

 

2015.1

2015.1

2015.1

2015.1

P1511

=

 

 

 

P1500

 

 

 

 

 

 

 

 

 

 

x = 5

 

0.0

755.0

 

2015.1

2018.1

 

755.1

P1503

 

 

 

 

 

 

2018.1

2018.1

 

2018.1

2018.1

 

2018.1

P1511

 

 

 

 

 

 

 

 

 

x = 6

 

0.0

755.0

 

2015.1

 

2050.1

755.1

P1503

 

 

2050.1

2050.1

 

2050.1

 

2050.1

2050.1

P1511

 

 

 

 

 

 

 

 

 

x = 7

 

0.0

755.0

 

2015.1

2018.1

2050.1

755.1

P1503

 

 

755.1

755.1

 

755.1

755.1

755.1

755.1

P1511

 

 

 

 

 

 

 

Example:

 

 

 

 

 

 

 

 

P1500 = 24

P1503 = 2015.1

 

 

 

 

 

 

 

 

P1511 = 755.0

 

 

 

 

 