Siemens 440 manual P28792 CI MUL, R2880, P28812 CI DIV, R2882, P28832 CI DIV, R2884

Models: 440

1 328
Download 328 pages 28.01 Kb
Page 255
Image 255

Issue 01/06

Parameter Description

P2879[2] CI: MUL 2

 

 

Min:

0:0

CStat:

CUT

Datatype: U32

Unit: -

Def:

755:0

P-Group:

TECH

Active: first confirm

QuickComm.: No

Max:

4000:0

Define inputs of Multiplier 2, result is in P2880.

Index:

P2879[0] : Connector input 0 (CI 0)

P2879[1] : Connector input 1 (CI 1)

Dependency:

P2802[9] is active level for the Multiplier.

Level

3

r2880

CO: MUL 2

 

Min:

-

 

Datatype: Float

Unit: %

Def:

-

 

P-Group: TECH

 

Max:

-

Level

3

Result of Multiplier 2.

Dependency:

P2802[9] is active level for the Multiplier.

P2881[2] CI: DIV 1

 

 

 

Min:

0:0

CStat:

CUT

Datatype: U32

Unit: -

Def:

755:0

P-Group:

TECH

Active: first confirm

QuickComm.: No

Max:

4000:0

Define inputs of Divider 1, result is in P2882.

Level

3

 

 

P2800

P2802[10]

 

Result = x1100%

 

 

P2881

x

 

 

 

 

 

 

 

 

 

 

Index 0

 

 

 

 

 

 

200%

 

 

 

x2

 

 

1

 

 

 

 

 

 

 

 

 

x1 100%

> 200%

 

 

 

 

 

 

 

 

 

r2882

If:

Result = 200%

 

x

 

 

 

 

 

 

 

Index 1

2

 

 

 

 

 

 

 

Result

 

 

 

 

 

 

 

 

 

 

 

 

-200%

 

 

x2

< -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x1 100%

 

 

 

 

 

 

x1

100%

 

 

 

 

 

Result = -200%

 

 

 

 

 

 

X2

 

 

 

x2

200%

 

 

 

 

 

 

 

 

 

 

 

Index:

P2881[0] : Connector input 0 (CI 0)

P2881[1] : Connector input 1 (CI 1)

Dependency:

P2802[10] is active level for the Divider.

r2882

CO: DIV 1

 

Min:

-

 

Datatype: Float

Unit: %

Def:

-

 

P-Group: TECH

 

Max:

-

Level

3

Result of Divider 1.

Dependency:

P2802[10] is active level for the Divider.

P2883[2] CI: DIV 2

 

 

 

Min:

0:0

CStat:

CUT

Datatype: U32

Unit: -

Def:

755:0

P-Group:

TECH

Active: first confirm

QuickComm.: No

Max:

4000:0

Define inputs of Divider 2, result is in P2884.

Index:

P2883[0] : Connector input 0 (CI 0)

P2883[1] : Connector input 1 (CI 1)

Dependency:

P2802[11] is active level for the Divider.

Level

3

r2884

CO: DIV 2

 

Min:

-

 

Datatype: Float

Unit: %

Def:

-

 

P-Group: TECH

 

Max:

-

Result of Divider 2.

Dependency:

P2802[11] is active level for the Divider.

Level

3

MICROMASTER 440

Parameter List

6SE6400-5BB00-0BP0

255

Page 255
Image 255
Siemens 440 manual P28792 CI MUL, R2880, P28812 CI DIV, R2882, P28832 CI DIV, R2884