Issue 01/06

Parameter Description

r1917[3]

Identified stator inductance 2

 

Min:

-

 

Datatype: Float

Unit: -

Def:

-

 

P-Group: MOTOR

 

Max:

-

Displays identified stator inductance.

Index:

r1917[0] : U_phase

r1917[1] : V_phase

r1917[2] : W_phase

Details:

See P1915 (identified nominal stator inductance)

Level

2

r1918[3]

Identified stator inductance 3

 

Min:

-

 

Datatype: Float

Unit: -

Def:

-

 

P-Group: MOTOR

 

Max:

-

Displays identified stator inductance.

Index:

r1918[0] : U_phase

r1918[1] : V_phase

r1918[2] : W_phase

Details:

See P1915 (identified nominal stator reactance)

Level

2

r1919[3]

Identified stator inductance 4

 

Min:

-

 

Datatype: Float

Unit: -

Def:

-

 

P-Group: MOTOR

 

Max:

-

Displays identified stator inductance.

Index:

r1919[0] : U_phase

r1919[1] : V_phase

r1919[2] : W_phase

Details:

See P1915 (identified nominal stator inductance)

Level

2

r1920[3]

Identified dyn. leak. inductance

 

Min:

-

Level

 

Datatype: Float

Unit: -

Def:

-

2

 

P-Group: MOTOR

 

Max:

-

 

Index:

Displays identified total dynamic leakage inductance.

 

 

 

 

r1920[0] : U_phase

 

 

 

 

 

 

 

 

 

 

r1920[1] : V_phase

 

 

 

 

 

r1920[2] : W_phase

 

 

 

 

r1925

Identified on-state voltage

 

Min:

-

Level

 

Datatype: Float

Unit: V

Def:

-

2

 

 

 

P-Group: INVERTER

 

Max:

-

 

Displays identified on-state voltage of IGBT.

r1926

Ident. gating unit dead time

 

Min:

-

 

Datatype: Float

Unit: us

Def:

-

 

P-Group: INVERTER

 

Max:

-

Displays identified dead time of gating unit interlock.

Level

2

P1930

Voltage setpoint for calibration

 

Min:

0

 

CStat:

CUT

Datatype: Float

Unit: V

Def:

0

 

P-Group:

INVERTER

Active: Immediately

QuickComm.: No

Max:

1000

Specifies reference voltage for generation of a test voltage vector (e.g. used for shunt calibration).

Level

4

P1931

Phase

 

 

 

Min:

1

 

CStat:

CUT

Datatype: U16

Unit: -

Def:

1

 

P-Group:

INVERTER

Active: Immediately

QuickComm.: No

Max:

6

Defines phase of voltage vector

Level

4

MICROMASTER 440

Parameter List

6SE6400-5BB00-0BP0

191

Page 191
Image 191