Siemens 440 manual P10063 Fixed frequency, P10073 Fixed frequency, P10083 Fixed frequency

Models: 440

1 328
Download 328 pages 28.01 Kb
Page 115
Image 115

Issue 01/06

Parameter Description

P1006[3] Fixed frequency 6

 

 

Min:

-650.00

CStat:

CUT

Datatype: Float

Unit: Hz

Def:

25.00

P-Group:

SETPOINT

Active: Immediately

QuickComm.: No

Max:

650.00

Defines fixed frequency setpoint 6.

Index:

P1006[0] : 1st. Drive data set (DDS)

P1006[1] : 2nd. Drive data set (DDS)

P1006[2] : 3rd. Drive data set (DDS)

Details:

See parameter P1001 (fixed frequency 1).

Level

2

P1007[3] Fixed frequency 7

 

 

Min:

-650.00

CStat:

CUT

Datatype: Float

Unit: Hz

Def:

30.00

P-Group:

SETPOINT

Active: Immediately

QuickComm.: No

Max:

650.00

Defines fixed frequency setpoint 7.

Index:

P1007[0] : 1st. Drive data set (DDS)

P1007[1] : 2nd. Drive data set (DDS)

P1007[2] : 3rd. Drive data set (DDS)

Details:

See parameter P1001 (fixed frequency 1).

Level

2

P1008[3] Fixed frequency 8

 

 

Min:

-650.00

CStat:

CUT

Datatype: Float

Unit: Hz

Def:

35.00

P-Group:

SETPOINT

Active: Immediately

QuickComm.: No

Max:

650.00

Defines fixed frequency setpoint 8.

Index:

P1008[0] : 1st. Drive data set (DDS)

P1008[1] : 2nd. Drive data set (DDS)

P1008[2] : 3rd. Drive data set (DDS)

Details:

See parameter P1001 (fixed frequency 1).

Level

2

P1009[3] Fixed frequency 9

 

 

Min:

-650.00

CStat:

CUT

Datatype: Float

Unit: Hz

Def:

40.00

P-Group:

SETPOINT

Active: Immediately

QuickComm.: No

Max:

650.00

Defines fixed frequency setpoint 9.

Index:

P1009[0] : 1st. Drive data set (DDS)

P1009[1] : 2nd. Drive data set (DDS)

P1009[2] : 3rd. Drive data set (DDS)

Details:

See parameter P1001 (fixed frequency 1).

Level

2

P1010[3] Fixed frequency 10

 

 

Min:

-650.00

CStat:

CUT

Datatype: Float

Unit: Hz

Def:

45.00

P-Group:

SETPOINT

Active: Immediately

QuickComm.: No

Max:

650.00

Defines fixed frequency setpoint 10.

Index:

P1010[0] : 1st. Drive data set (DDS)

P1010[1] : 2nd. Drive data set (DDS)

P1010[2] : 3rd. Drive data set (DDS)

Details:

See parameter P1001 (fixed frequency 1).

Level

2

P1011[3] Fixed frequency 11

 

 

Min:

-650.00

CStat:

CUT

Datatype: Float

Unit: Hz

Def:

50.00

P-Group:

SETPOINT

Active: Immediately

QuickComm.: No

Max:

650.00

Defines fixed frequency setpoint 11.

Index:

P1011[0] : 1st. Drive data set (DDS)

P1011[1] : 2nd. Drive data set (DDS)

P1011[2] : 3rd. Drive data set (DDS)

Details:

See parameter P1001 (fixed frequency 1).

Level

2

MICROMASTER 440

Parameter List

6SE6400-5BB00-0BP0

115

Page 115
Image 115
Siemens 440 manual P10063 Fixed frequency, P10073 Fixed frequency, P10083 Fixed frequency, P10093 Fixed frequency