Issue 01/06

Parameter Description

P2190[3] Lower torque threshold 3

 

Min:

0.0

CStat:

CUT

Datatype: Float

Unit: Nm

Def:

0.0

P-Group:

ALARMS

Active: Immediately

QuickComm.: No

Max:

99999.0

Level

2

Lower limit threshold value 3 for comparing actual torque.

Index:

P2190[0] : 1st. Drive data set (DDS)

P2190[1] : 2nd. Drive data set (DDS)

P2190[2] : 3rd. Drive data set (DDS)

Details:

See P2182 (belt threshold frequency 1).

P2192[3] Time delay for belt failure

 

Min:

0

Level

 

CStat:

CUT

Datatype: U16

Unit: s

Def:

10

2

 

 

 

P-Group:

ALARMS

Active: Immediately

QuickComm.: No

Max:

65

 

P2192 defines a delay before warning/trip becomes active. It is used to eliminate events caused by transient conditions. It is used for both methods of fault detection.

Index:

 

P2192[0]

: 1st. Drive data set (DDS)

P2192[1]

: 2nd. Drive data set (DDS)

P2192[2]

: 3rd. Drive data set (DDS)

r2197

 

CO/BO: Monitoring word 1

 

 

 

Min:

-

 

Level

 

 

 

 

Datatype: U16

Unit: -

 

Def:

-

 

2

 

 

 

 

 

 

 

 

 

P-Group:

ALARMS

 

 

 

 

 

Max:

-

 

 

 

 

Monitoring word 1 which indicates the state of monitor functions. Each bit represents one monitor function.

 

Bitfields:

 

 

 

 

 

 

 

 

 

 

 

 

Bit00

f_act <=

P1080

(f_min)

 

0

NO

1

YES

 

 

Bit01

f_act <=

P2155

(f_1)

 

 

0

NO

1

YES

 

 

Bit02

f_act >

P2155

(f_1)

 

 

0

NO

1

YES

 

 

Bit03

f_act >

zero

 

 

 

0

NO

1

YES

 

 

Bit04

f_act >=

setp. (f_set)

 

0

NO

1

YES

 

 

Bit05

f_act <=

P2167

(f_off)

 

0

NO

1

YES

 

 

Bit06

f_act >=

P1082

(f_max)

 

0

NO

1

YES

 

 

Bit07

f_act ==

setp. (f_set)

 

0

NO

1

YES

 

 

Bit08

Act. current r0068 >

P2170

 

0

NO

1

YES

 

 

Bit09

Act. unfilt. Vdc

<

P2172

 

0

NO

1

YES

 

 

Bit10

Act. unfilt. Vdc

>

P2172

 

0

NO

1

YES

 

 

Bit11

Load missing

 

 

 

0

NO

1

YES

r2198

CO/BO: Monitoring word 2

 

Min:

-

 

Datatype: U16

Unit: -

Def:

-

 

P-Group: ALARMS

 

Max:

-

Level

2

Monitoring word 2 which indicates the state of monitor functions. Each bit represents one monitor function.

Bitfields:

 

 

 

 

 

 

 

 

Bit00

f_act

<=

P2157

(f_2)

0

NO

1

YES

Bit01

f_act

>

P2157

(f_2)

0

NO

1

YES

Bit02

f_act

<=

P2159

(f_3)

0

NO

1

YES

Bit03

f_act

>

P2159

(f_3)

0

NO

1

YES

Bit04

f_set

<

P2161

(f_min_set)

0

NO

1

YES

Bit05

f_set >

0

 

 

0

NO

1

YES

Bit06

Motor blocked

 

0

NO

1

YES

Bit07

Motor pulled out

 

0

NO

1

YES

Bit08

I_act

r0068 >

P2170

0

NO

1

YES

Bit09

m_act

> P2174 & setpoint reached

0

NO

1

YES

Bit10

m_act

> P2174

 

0

NO

1

YES

Bit11

Belt failure warning

0

NO

1

YES

Bit12

Belt failure trip

 

0

NO

1

YES

MICROMASTER 440

Parameter List

6SE6400-5BB00-0BP0

221

Page 221
Image 221
Siemens 440 manual P21903 Lower torque threshold, P21923 Time delay for belt failure, R2197 CO/BO Monitoring word, 221