Issue 01/06

Parameter Description

P1489[3] Droop scaling

 

 

Min:

0.00

CStat:

CUT

Datatype: Float

Unit: -

Def:

0.05

P-Group:

CONTROL

Active: Immediately

QuickComm.: No

Max:

0.50

Level

3

Defines amount of droop in per unit at full load in [%].

Index:

P1489[0] : 1st. Drive data set (DDS)

P1489[1] : 2nd. Drive data set (DDS)

P1489[2] : 3rd. Drive data set (DDS)

Note:

If 0 is entered as value, no droop is applied.

r1490

CO: Droop frequency

 

Min:

-

 

Datatype: Float

Unit: Hz

Def:

-

 

P-Group: CONTROL

 

Max:

-

Displays output signal of droop function.

Level

3

This result of droop calculation is subtracted from the speed controller setpoint.

P1492[3] Enable droop

 

 

Min:

0

CStat:

CUT

Datatype: U16

Unit: -

Def:

0

P-Group:

CONTROL

Active: first confirm

QuickComm.: No

Max:

1

Enables droop.

Possible Settings:

0Disabled

1Enabled

Index:

P1492[0] : 1st. Drive data set (DDS)

P1492[1] : 2nd. Drive data set (DDS)

P1492[2] : 3rd. Drive data set (DDS)

Dependency:

Effective only if droop scaling P1489 > 0.

Level

3

MICROMASTER 440

Parameter List

6SE6400-5BB00-0BP0

171

Page 171
Image 171
Siemens 440 manual P14893 Droop scaling, R1490 CO Droop frequency, P14923 Enable droop, 171