r0031

CO: Act. filtered torque

 

Min:

-

 

Datatype: Float

Unit: Nm

Def:

-

 

P-Group: CONTROL

 

Max:

-

Displays electrical torque.

Level

2

mM =

3

Lm

Zp ⋅ Ψ rd isq

2

LR

 

 

 

Valid for V/f-caracteristic:

isq

u is cosϕ −

Rs2 is

e

 

 

 

mM : Motor torque

Zp : Pole pair number

Ψrd : Rotor flux

LR : Rotor inductance

Lm : Magnetizing inductance

isq : Torque-generating current e : Motor counter EMF

Output value will be zero at low speeds when the current injection is active (r1751.5 = 1).

Note:

The electrical torque is not the same as the mechanical torque, which can be measured on the shaft. Due to windage and friction a part of the electrical torque is lost in the motor.

r0032

CO: Act. filtered power

 

Min:

-

 

Datatype: Float

Unit: -

Def:

-

 

P-Group: CONTROL

 

Max:

-

Displays motor power (power output at the motor shaft).

Level

2

 

 

Pmech = ω ⋅ M =

2 ⋅ π

f M

 

 

 

ω , M

1

 

 

r0022

 

 

r0032[kW ]=

 

 

2 π

[1/min]r0031[Nm]

Motor

 

 

 

 

 

1000

60

 

 

 

 

 

 

r0032[hp] = 0.75 r0032[kW]

Dependency:

Value is displayed in [kW] or [hp] depending on setting for P0100 (operation for Europe / North America).

r0035[3]

CO: Act. motor temperature

 

Min:

-

 

Datatype: Float

Unit: °C

Def:

-

 

P-Group: MOTOR

 

Max:

-

Index:

Displays measured motor temperature.

 

 

 

 

 

 

 

Level

2

r0035[0] : 1st. Drive data set (DDS)

r0035[1] : 2nd. Drive data set (DDS)

r0035[2] : 3rd. Drive data set (DDS)