Configuration - T1 Controller Mode

threshold

Use the Controller T1 threshold command to define the interval and threshold levels for this T1.

Syntax: (config-cont-t1-{n})# threshold {dailymin15} {bescssdmeslcvlespcvsefssesuas} {value}

Threshold Settings

Minute 15

Daily

BES - Bursty Errored Seconds

Default is 0.

Default is 0.

Defect Threshold

Range is 0 - 900

Range is 0 - 86400

 

 

 

CSS - Controller Slip Seconds

Default is 0.

Default is 0.

Defect Threshold

Range is 0 - 900

Range is 0 - 86400

 

 

 

DM - Degraded Minutes

Default is 0.

Default is 0.

Threshold

Range is 0 - 15

Range is 0 - 1440

 

 

 

ES - Errored Seconds Defect

Default is 0.

Default is 0.

Threshold

Range is 0 - 900

Range is 0 - 86400

 

 

 

LCV - Line Code Violations

Default is 0.

Default is 0.

Defect Threshold

Range is 0 - 1389600

Range is 0 - 133401600

 

 

 

LES - Line Errored Seconds

Default is 0.

Default is 0.

Defect Threshold

Range is 0 - 900

Range is 0 - 86400

 

 

 

PCV - Path Code Violation

Default is 0.

Default is 0.

Defect Threshold

Range is 0 - 1389600

Range is 0 - 133401600

 

 

 

SEFS - Severely Errored

Default is 0.

Default is 0.

Frame Seconds Threshold

Range is 0 - 900

Range is 0 - 86400

 

 

 

SES - Severely Errored

Default is 0.

Default is 0.

Seconds Threshold

Range is 0 - 900

Range is 0 - 86400

 

 

 

UAS - Unavailable Seconds

Default is 0.

Default is 0.

Defect Threshold

Range is 0 - 900

Range is 0 - 86400

 

 

 

Example: (config-cont-t1-1)# threshold 15min les 1200

Supported Platforms: Adit 3104, Adit 3200, Adit 3500

6-12

Adit 3000 (Rel. 1.6) and MSR Card (Rel 2.0) CLI