Carrier Access none manual Show alarms

Models: none

1 496
Download 496 pages 60.9 Kb
Page 31
Image 31

User Mode

show alarms

Use the show alarms command to display the active alarms.

Syntax: > show alarms [t1 portlcc number]

{alertallcriticalinfomajorminor}

Field

Definition

t1 port

Display alarms for a specific port.

 

Adit 3104: Value must be 1.

 

Adit 3500: Range = 1-4.

 

 

lcc number

Display alarms for a specific Link Cross-Connect (LCC).

 

MSR: Range = 1-8.

 

 

alert

Filter alert alarms (threshold crossing).

 

 

all

Display all alarms.

 

 

critical

Filter critical alarms.

 

 

info

Filter information alarms.

 

 

major

Filter major alarms.

 

 

minor

Filter minor alarms.

 

 

Example: Adit 3500> show alarms all

 

 

 

 

Alarm

 

Severity

 

Time

Alarm LOS T1

4

Major

Jan

1

00:00:08 2007

Alarm LOS T1

3

Major

Jan

1

00:00:08 2007

Alarm PRI T1 2 - Line NOT Ready

Major

Jan

1 00:00:08 2007

Supported Platforms: Adit 3104, Adit 3200, Adit 3500, MSR

Adit 3000 (Rel. 1.6) and MSR Card (Rel 2.0) CLI