Avaya P330-ML-ML manual Snmp-server informs

Models: P330-ML-ML

1 320
Download 320 pages 24.24 Kb
Page 218
Image 218

Chapter 2 Avaya P330-ML Layer 2 CLI Commands

udp-portKeyword that specifies that a specific UDP port on the target

(Optional) host should be used when sending notifications to the host. The default UDP port is 162.

port

The UDP port on the target host to which notifications are sent.

notification List of notification types. Each types combines related

-type-listnotifications. You can enable or disable notification generations

(Optional) on a per group basis. For example, the swRedundancy type groups new and delete software redundancy notifications.

If no notification-type-list is specified, the default, all, is used.

all/* – All traps

generic – Generic traps

config – Config change notifications

eth-port-faults– Ethernet port fault notifications

sw-redundancy– Software redundancy notifications

temperature – Temperature warning notifications

cam-change– Changes in CAM notifications

l3-faults– Layer 3 faults, including duplicate IP and VLAN violations

lag-event– Link aggregation faults and configuration changes

policy – Changes in policy notifications (for L3 devices)

link-down-faults– ITC proprietary link down notifications

supply – Power supply notifications (main and backup)

fan – FAN faults notifications (main and backup)

cascade – Cascade connection fault notifications.

Note that the list of notification names is proprietary to ITC.

Example:

P330-N>snmp-server host 149.49.38.221 informs v3 noauth charlieBrown

Done!

snmp-server informs

User level: supervisor

Use the snmp-server informs command to configure inform parameters.

204

Avaya P330-ML Reference Guide

Page 218
Image 218
Avaya P330-ML-ML manual Snmp-server informs