Chapter 2 Avaya P330-ML  Layer 2 CLI Commands
rmon alarm
User level: privileged, supervisor.
Use the rmon alarm command to create a new RMON alarm entry.
The syntax for this command is:
rmon alarm <Alarm Number> <variable> <interval> <sample type> 
| Alarm Number | This is the alarm index number of this entry (it is advisable to | 
| 
 | use the same interface number as your alarm index number.) | 
| variable | The instance of an RMON statistic. | 
| interval | The interval between 2 samples. | 
| sample type | This can be set to either delta (the difference between 2 | 
| 
 | samples) or an absolute value. | 
| rising threshold | This sets the upper threshold for the alarm entry. | 
| rising event | The RMON event entry that will be notified if the upper | 
| 
 | threshold is passed. | 
| falling | This sets the lower threshold for the alarm entry. | 
| threshold | 
 | 
| falling event | The RMON event entry that will be notified if the lower | 
| 
 | threshold is passed. | 
| startup alarm | The instances in which the alarm will be activated. The | 
| 
 | possible parameters are: Rising, Falling, risingOrfalling. | 
| owner | Owner name string. | 
| Example: | 
 | 
alarm 1026 was created successfully
| 56 | Avaya  | 