Configuring System Information 165
Running Cable Diagnostics
The Diagnostics page contains links to pages for performing virtual cable tests on copper and fiber
optic cables. Toopen the Diagnostics page, click System Diagnostics in the tree view.
This section contians the following topics:
"Viewing Copper Cable Diagnostics" on page165
"Viewing Optical Transceiver Diagnostics" on page167

Viewing Copper Cable Diagnostics

The Integrated Cable Test for Copper Cables page contains fields for performing tests on copper cables.
Cable testing provides information about where errors occurred in the cable, the last time a cable test
was performed, and the type of cable error which occurred. The tests use Time Domain Reflectometry
(TDR) technology to test the quality and characteristics of a copper cable attached to a port. Cables up
to 120 meters long can be tested. Cables are tested when the ports are in the down state, with the
exception of the Approximated Cable Length test.
To open the Integrated Cable Test for Copper Cables page, click System Diagnostics Integrated
Cable Test in the tree view.
Figure 6-51. Integrated Cable Test for Copper Cables