Figure 6-54. Optical Transceiver Diagnostics Table

In addition to the fields in the Optical Transceiver Diagnostics page, the Optical Transceiver Diagnostics Table contains the following field:

Unit No. — The unit number for which the cable is displayed.

N/A — Not Available, N/S - Not Supported, W - Warning, E - Error

Performing Fiber Optic Cable Tests Using CLI Commands

The following table contains the CLI command for performing fiber optic cable tests.

Table 6-32. Fiber Optic Cable Test CLI Commands

CLI Command

Description

 

 

show fiber-ports optical-

Displays the optical transceiver

transceiver [interface]

diagnostics.

[detailed]

 

 

 

The following is an example of the CLI command:

Console# show fiber-ports optical-transceiver detailed

Port

Temp

Voltage

Current

Output

Input

POWER

LOS

 

[C]

 

[Volt]

[mA]

[mWatt]

TX

Fault

 

 

 

 

 

 

[mWatt]

 

----

----

------

-----

------

------

------

-----

1/g1

48

5.15

50

1.789

1.789

No

No

1/g2

43

5.15

10

1.789

1.789

No

No

Configuring System Information

169

Page 169
Image 169
Dell 3548 manual Console# show fiber-ports optical-transceiver detailed, Optical Transceiver Diagnostics Table