Switching Between Stack Masters
1Open the Stack Management page.
2Check the Switch Stack Control from Unit 1 to Unit 2 check box.
3Click Apply Changes.
A confirmation message displays.
4Click OK.
The device is reset. After the device is reset, a prompt for a user name and password displays.
Managing Stacks Using the CLI Commands
The following table summarizes the equivalent CLI commands for viewing fields displayed in the Stack Management page.
Table
CLI Command | Description |
|
|
stack reload | Reloads stack members. |
|
|
stack master | Forces the stack master selection |
|
|
Resetting the Device
The Reset page enables the device to be reset from a remote location. Save all changes to the Startup Configuration file before resetting the device. This prevents the current device configuration from being lost. For more information about saving Configuration files, see "Copy Files" on page 239. To open the Reset page, click System → General → Reset in the tree view.
Figure 6-9. Reset
The Reset page contains the following field:
Reset Unit No. — Resets the selected stacking member.