9

Configuring Tape Device Extension

selecting the Show Source WWN Filtering check box on the UCM FibreChannel Advanced tab. This field is used to define which server can access a LUN, based upon the server’s WWN. It prevents more than one server from accessing a LUN.

Table 9-6Edge 10 Source WWN Filtering

Device

 

 

Mapped

 

LUN

Device WWN

Device Type

Lun

Source WWN

 

 

 

 

 

0

 

McDATA unit

0

 

0

A1:A1:A1:A1:A1:A1:A1:A1

Tape A1

1

AA:AA:AA:AA:AA:AA:AA:AA

0

A2:A2:A2:A2:A2:A2:A2:A2

Tape A2

2

AA:AA:AA:AA:AA:AA:AA:AA

0

C4:C4:C4:C4:C4:C4:C4:C4

Tape C4

3

CC:CC:CC:CC:CC:CC:CC:CC

0

FF:02:FF:02:FF:02:FF:02

Media Changer 2

4

00:00:00:00:00:00:00:00

In Table 8-6 above, Server A and Server C need to see Media Changer 2 (based on the illustration in Figure 8-3). Using the default WWN of all zeros in the Source WWN field will allow any WWN access to that LUN.

Table 9-7Edge 20 Source WWN Filtering

Device

 

 

Mapped

 

LUN

Device WWN

Device Type

LUN

Source WWN

 

 

 

 

 

0

 

McDATA unit

0

 

0

B2:B2:B2:B2:B2:B2:B2:B2

Tape B2

1

BB:BB:BB:BB:BB:BB:BB:BB

0

FF:01:FF:01:FF:01:FF:01

Media Changer 1

2

BB:BB:BB:BB:BB:BB:BB:BB

Configuring Tape Device Extension

To configure your Edge for a FC/SCSI Tape Pipelining implementation, the following eight procedures are necessary. Complete each procedure in the order shown below:

1.Gathering the IP Addresses

2.Starting UltraNet ConfigManager

3.Adding Nodes for an Ethernet WAN Configuration

9-8

McDATA UltraNet Edge 3000 User Guide

 

 

Page 216
Image 216
McDATA 3000 manual Configuring Tape Device Extension, Device WWN Device Type Lun Source WWN