Manually Configure the Maintenance IP Port using the

10.Set up the terminal emulator on the PC to communicate with the UltraNet Edge 3000. Use the following parameters for the terminal emulator:

Bits per second = 38400

Data Bits = 8

 

Parity = None

Stop Bits = 1

• Flow = None

11.Power up the UltraNet Edge 3000.

12.To display the prom> prompt, press the Enter key on your keyboard.

13.Type setNetCfg "Maintenance IP Port", "Default Gateway", "Subnetmask" at the Prom prompt, as shown below:

prom> setNetCfg "192.168.10.1", "192.168.10.3", "255.255.255.0"

NOTE: Please refer to the UltraNet Edge Storage Router Configuration IP Address Worksheet in Appendix J to complete this step. The addresses needed to configure these parameters are shown in Fields A, B, F, and G. Quotation marks and commas must be used when using this command.

14.At the prom> prompt, type reset. The UltraNet Edge 3000 will reboot and bring you to the operating system prompt.

tm.0x0>

15.Connect the Ethernet straight through Category 5 cable to the RJ-45 connector labeled Ethernet on the UltraNet Edge 3000. Connect the other end of the cable to the active Ethernet network connection.

16.Use the UltraNet ConfigManager application to configure the entire network including the remote node.

Skip the Set Initial Config step in the UltraNet ConfigManager application for the remote node that was manually configured using the Command Line Interface. The Set Initial Config step is normally used to configure the Maintenance IP Port in UltraNet ConfigManager.

H-2

UltraNet™ Edge Storage Router 3000 User Guide

Page 402