This section provides information for each of the diagnostic programs currently available for the UltraNet Edge 3000.

NOTE: Some tests may take several minutes to complete, while others will take very little time. At any time you can issue a control-c (^C) key to interrupt and stop a diagnostic test.

CHARM Diagnostic The UltraNet Edge 3000 CHARM ATM/POS diagnostic program

Program (ACHT) resides on the UltraNet Edge 3000’s flash drive as the file acht.dll. Using the PROM interface, the file must be loaded into memory and executed from there.

This program tests the UltraNet Edge 3000’s CHARM ATM/POS WAN interface and verifies that it can perform memory transfer functions across the primary PCI bus and local memory. Test data can be looped back either internally or externally.

Individual tests can be selected from the menu or the “Execute All” option can be used to run tests 3 thru 10, and 17.

On Bus # 2 Device # 1

Device/Vendor ID read from board 0 PCI ConfigWord0 = 1029103C

On Bus # 3 Device # 1

Device/Vendor ID read from board 0 PCI ConfigWord0 = 00A11014

Sub Sys ID / Vendor ID read from offset 0x002C Reg = 015E1014

+++ IBM CHARM Rev 2.7 Device Found On Bus #3, Device #1!

Quick EPROM Check was Successful.

Doing Quick Charm Memory Test. Quick Memory Test Passed.

PHY Type Detected is PM5384 OC-3 type.

**** 1 ATM Board Found, OC-3 Count = 1 ****

Clearing Buffer Memory - 128MB

*> SBTM ATM CHARM Diagnostic Test Revision 1.1 – February 11, 2002 <*