UltraNet ConfigManager Upgrade

Thu Sep 13 16:55:36 NOTICE: CNT511:nu_cfgd:1:5:0 ui_envput: Environment variable put (_RPMCPUCheckDisabled) (YES) command received.

User Entry:

cfg envput _RPMCPUCheckDisabled YES Ok.

rpm erase cmntwebview rpm install WV32.RPM rpm query -a CMNTnucleus-V3.1.1.2-0 CMNTdiag-V3.1.1.2-0 CMNTsm-V3.1.1.2-0 CMNTwebview-V3.2-0

cfg envput _RPMCPUCheckDisabled NO

Thu Sep 13 16:56:49 NOTICE: CNT511:nu_cfgd:1:5:0 ui_envput: Environment variable put (_RPMCPUCheckDisabled) (NO) command received.

User Entry:

cfg envput _RPMCPUCheckDisabled NO Ok.

The above data shows a successful installation without any errors.

After installing or upgrading WebView, the webserver needs to be restarted so it can flush all the old WebView information and load the new information from the current WebView program.

4. Issue the ews reinit command at the UltraNet Edge 3000 prompt. example:

tm.0x10> ews reinit

UltraNet ConfigManager Upgrade

 

 

UltraNet ConfigManager is a graphical configuration tool that

 

 

provides a point-and-click process for designing and configuring

 

 

UltraNet Edge 3000 nodes. This tool allows the user to self-configure

 

 

and manage network configuration modifications.

 

 

This section contains the procedure for upgrading the UltraNet

 

 

ConfigManager to the most current version of software.

 

 

 

 

Verify the Current

To verify the version of software installed on your PC, click on the

 

Version of UltraNet

UltraNet ConfigManager Help menu, then About. The version is

 

ConfigManager

displayed in the About UltraNet ConfigManager screen.

 

McDATA UltraNet Edge 3000 User Guide

11-14

 

 

 

Page 276
Image 276
McDATA 3000 manual UltraNet ConfigManager Upgrade, Verify the Current, Version of UltraNet, Tm.0x10 ews reinit