Table F-1

SNMP Configuration Screen Fields (Continued)

 

 

 

 

 

 

Field

Description

 

 

 

 

 

 

Write Community

Specifies the Write Community. This field can hold up to 255

 

 

 

alphanumeric characters and can be upper and lower case

 

 

 

letters.

 

 

 

 

 

 

Traps

This section can define six SNMP trap destinations.

 

 

 

Click the Asterisk (*) to enter a valid IP address in the

 

 

 

Destination field.

 

 

 

 

 

 

Host Access

This section allows an unlimited number of specific

 

 

 

hosts to be either allowed or denied access.

 

 

 

For example, you can use this field to deny access to a

specific host when the Default Action field (above) is set to Allow.

Adding an SNMP Trap Destination

Deleting an SNMP Destination

Sending Test Trap

Click on a row that beings with an asterisk (*). When you click on the row, a new trap destination is created, and default values appear in the columns. Enter the IP address for the SNMP trap destination and select a trap level (see the list in step , on page -4).

0.0.0.0 is not a valid SNMP trap destination.

Click on the row selector at the left of the row of the SNMP trap destination you want to delete. The row becomes highlighted to indicate it is selected, press Delete. Repease these steps for each SNMP trap destination you want to delete.

New functionality was incorporated in the SNMP agent to allow a user to send SNMP test traps. The UltraNet Edge 3000 SNMP agent forwards traps to defined trap destinations based on severity levels. The severity levels in the UltraNet Edge 3000 range from 0-7. The lower the number the more critical the message.

To send a test trap and verify that it was sent, issue the following command:

tm0x10.> snmp sendtrap x

Where: x is the severity level

This command sends a test trap to the defined trap destination.