McDATA 3000 manual 11-8

Models: 3000

1 428
Download 428 pages 38.05 Kb
Page 270
Image 270

11

Upgrading the UltraNet Edge 3000 Software

FTP the New UltraNet Edge 3000 Software

This will reset the UltraNet Edge 3000 and bring up the maintenance IP address.

8.Using Windows Dial-up Networking, establish a PPP session from the local PC to the new UltraNet Edge 3000.

9.Using the most current version of UCM, display the network map created in the previous version of UCM.

10.Start the Hardware Replacement Wizard by right-clicking on the UltraNet Edge 3000 node>Tools>Replace Node (Hardware Replacement) for the new UltraNet Edge 3000.

11.Update the serial number and license information.

12.Deliver the configuration to the new UltraNet Edge 3000.

Use the following procedure to FTP to the new UltraNet Edge 3000 and retrieve the new software:

1.Telnet to the new UltraNet Edge 3000 and issue the abort command.

This will boot up the UltraNet Edge 3000 and invoke the new configurations.

2.Telnet to the UltraNet Edge 3000 that is currently running OS 3.1.1.1 (or any subsequent OS 3.x.x.x version).

Where xxx = the version of the UltraNet Edge 3000 before the upgrade.

3.Issue the tankio down x (where x = circuit ID 1, 2, etc) command for every defined circuit.

4.Issue the following commands:

Edge> net ftp xxx.xxx.xxx.xxx

(where xxx.xxx.xxx.xxx = the IP WAN address of the new UltraNet Edge 3000)

Name <xxx.xxx.xxx.xxx>: press ENTER

Password: xxxxxxxx

(where xxxxxxxx = the proper password)

A successful FTP login should occur.

5.The output to the screen should read, “Using binary mode to transfer files”. If not, issue the binary command at the FTP prompt.

11-8

McDATA UltraNet Edge 3000 User Guide

 

 

Page 270
Image 270
McDATA 3000 manual 11-8